Custom-made low-voltage distribution boards and control panels made in Switzerland, with a rated current up to 6300 A. They are used in buildings, at industrial sites and in tunnels.

Rated current
up to 6300 A
Short-circuit current
up to 85 kA (Ipk) for certified systems
Types
main and secondary distribution boards, control panels (HVAC, building automation, tunnels), power cabinets
Standards
EN 61439-1/2/3, EN 60204

Technical specifications

Rated currentup to 6300 A
Short-circuit currentup to 85 kA (Ipk) for certified systems
Typesmain and secondary distribution boards, control panels (HVAC, building automation, tunnels), power cabinets
StandardsEN 61439-1/2/3, EN 60204

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The boards are assembled for the project, so the set of devices and the incoming and outgoing lines are determined by the order. A rated current up to 6300 A makes it possible to build main distribution boards of large facilities as well. For certified systems a short-circuit current up to 85 kA (Ipk) is stated. Main and secondary distribution boards, control panels for HVAC, building automation and tunnels, and power cabinets are produced. The power part is designed to EN 61439-1/2/3, and the electrical equipment of machines and mechanisms to EN 60204.

How to choose

Three values are needed for selection. These are the rated current of the incoming line, the calculated short-circuit current at the installation point and the type of board — main distribution, secondary or control. If the short-circuit current at the site reaches 85 kA, make sure that the selected system is among the certified ones. For automation and ventilation, control panels to EN 60204 are ordered. The catalogue gives only limit values, so the set of devices, dimensions and version are agreed at the project stage.

Request a price and lead time

Low-voltage distribution boards and control panels up to 6300 A, Rauscher & Stoecklin. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

For what maximum current are the boards made?

The rated current reaches 6300 A.

What short-circuit withstand do these boards have?

For certified systems up to 85 kA (Ipk) is stated. The specific value depends on the version of the board.

To which standards are low-voltage boards of this type made?

Power boards are made to EN 61439-1/2/3, and the electrical equipment of machines to EN 60204.

Are there standard board sizes?

The boards are made to order for a specific project, so the size is set by the site, and the limit rated current is 6300 A.

For which facilities are the boards intended?

For buildings, industrial sites and tunnels. There are main distribution boards, secondary boards, control panels and power cabinets.

Similar products

Low-voltage equipment

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.