RN-W — low-voltage switchgear for substations up to 2000 A

The RN-W low-voltage switchboard is rated for a current of 1250, 1600 or 2000 A and a short-time withstand current of 35 kA for 1 s. It is installed in urban transformer substations, industrial plants and commercial buildings, and in substations it serves as the main LV switchgear.

Rated current
1250 / 1600 / 2000 A
Short-time withstand current
35 kA (1 s)
Peak withstand current
up to 77 kA
Earthing systems
TN-S, TN-C, TN-C-S, TT, IT

Technical specifications

Rated current1250 / 1600 / 2000 A
Short-time withstand current35 kA (1 s)
Peak withstand currentup to 77 kA
Earthing systemsTN-S, TN-C, TN-C-S, TT, IT
Featuresswitch-disconnector replacement without de-energizing, live extension

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The peak withstand current of the assembly reaches 77 kA. The switchboard works in TN-S, TN-C, TN-C-S, TT and IT earthing systems, so it suits both regional utility networks and sites with an isolated neutral. The switch-disconnector is replaced without de-energizing, so repairing one line does not disconnect consumers on neighboring feeders. The switchboard can also be extended with new sections while live, which is convenient when the substation load grows in stages. The design is adapted to the tight space of a transformer substation, where the switchboard stands next to the transformer and the medium-voltage unit.

How to choose

The rated current is chosen according to the transformer power, and within the RN-W series it is 1250, 1600 or 2000 A. If the main switchboard has to carry up to 6300 A or withstand an internal arc of 105 kA for 1 s, the ZR-W is the right choice. For secondary automation and metering boards with busbars of 250–1600 A the INSTAL-BLOK is more convenient, and for currents up to 7000 A the manufacturer assembles the Sivacon S8.

Request a price and lead time

RN-W — low-voltage switchgear for substations up to 2000 A. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What rated current is the RN-W switchboard available for?

The switchboard is made for 1250, 1600 or 2000 A, and the choice depends on the power of the substation transformer.

What short-circuit current can the RN-W withstand?

The short-time withstand current is 35 kA for 1 s, and the peak withstand current reaches 77 kA.

In which earthing systems can the RN-W be used?

In TN-S, TN-C, TN-C-S, TT and IT systems.

Can the switch-disconnector in the RN-W be replaced without shutting down the substation?

Yes, the design allows the switch-disconnector to be replaced without de-energizing, and the switchboard to be extended while live.

How does the RN-W differ from the ZR-W?

The RN-W is rated for a current of up to 2000 A and 35 kA withstand, while the ZR-W works in the 1000–6300 A range with a short-time withstand current of up to 105 kA and is intended for main switchgear.

Similar products

Low-voltage equipment

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.