МІК-111 — universal microprocessor PID controller

accuracy 0.2 % · response time 0.1 s · 24 or 230 V AC/DC supply · RS-485, Modbus RTU

The МІК-111 is a universal microprocessor PID controller for automatic regulation and monitoring of process parameters in industrial plants. It accepts signals from resistance thermometers, thermocouples and standard current or voltage sources. The input is processed with digital filtering and scaling. The controller generates a control action using PID control via an analogue, pulse or PWM output, or in ON/OFF or three-position mode. Manual and automatic control are supported, as well as out-of-limit alarms. Accuracy is 0.2 %, response time is 0.1 s, and the unit runs on a 24 or 230 V AC/DC supply. It has 1 analogue input, 1 analogue output and 2 discrete outputs, which can be transistor or relay types. It also provides an RS-485 interface with Modbus RTU, 500 V galvanic isolation of circuits and non-volatile memory. Typical uses include temperature, pressure, level, humidity and flow control, including in the food industry. The model has been discontinued and is replaced by the МІК-311-К4. Discontinued. Current replacement: МІК-311-К4.

Input signal type
01: 0-5 mA DC; 02: 0-20 mA DC; 03: 4-20 mA DC; 04: 0-10 V; 05: 0-75 mV; 06: 0-200 mV; 07: 0-2 V; 08: ТСМ 50М; 09: ТСМ 100М; 10: ТСМ гр.23; 11: ТСП 50П; 12: ТСП 100П; 13: ТСП гр.21; 14: ТХА (K); 15: ТХК (L); 16: ТЖК (J); 17: ТХКн (E); 18: ТПП10 (S); 19: ТПР (B); 20: ТВР-1 (А-1)
Analogue output range
01: 0-5 mA; 02: 0-20 mA; 03: 4-20 mA; 04: 0-10 V
Discrete output type
T: transistor; P: relay
Supply voltage
230: 230 V AC/DC; 24: 24 V AC/DC

Technical specifications

Input signal type01: 0-5 mA DC; 02: 0-20 mA DC; 03: 4-20 mA DC; 04: 0-10 V; 05: 0-75 mV; 06: 0-200 mV; 07: 0-2 V; 08: ТСМ 50М; 09: ТСМ 100М; 10: ТСМ гр.23; 11: ТСП 50П; 12: ТСП 100П; 13: ТСП гр.21; 14: ТХА (K); 15: ТХК (L); 16: ТЖК (J); 17: ТХКн (E); 18: ТПП10 (S); 19: ТПР (B); 20: ТВР-1 (А-1)
Analogue output range01: 0-5 mA; 02: 0-20 mA; 03: 4-20 mA; 04: 0-10 V
Discrete output typeT: transistor; P: relay
Supply voltage230: 230 V AC/DC; 24: 24 V AC/DC
Accuracy0.2 %
Response time0.1 s
Power consumption (AC)max. 6.5 VA
Current consumption (DC)max. 180 mA
Isolation voltage500 V
Max. transistor output voltage40 V
Inputs/outputs1 analogue input, 1 analogue output, 2 discrete outputs (transistor or relay)
Interface / protocolRS-485 / Modbus RTU
Ingress protectionIP30
Mountingpanel
Dimensions48x96x162 mm
Weightmax. 0.35 kg
Statusdiscontinued, current replacement: МІК-311-К4

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

When ordering, specify the input code (01–20) according to the sensor type: current, voltage, ТСМ, ТСП or a thermocouple of the required calibration. Then select the analogue output range: 0-5 mA, 0-20 mA, 4-20 mA or 0-10 V. Discrete outputs are available as transistor (T) or relay (P) types. The supply can be 24 or 230 V AC/DC. For new projects, the МІК-311-К4 is recommended.

Similar products

Low-voltage equipment

Request a price and lead time

МІК-111 — universal microprocessor PID controller. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.