Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

LOW-VOLTAGE EQUIPMENT

МІК-111Н — universal microprocessor PID controller

error ≤ 0.2 % · 1 universal analogue input · RS-485, Modbus RTU · supply 230 V AC / 24 V DC

The МІК-111Н is a single-channel microprocessor controller for automatic regulation of process parameters such as temperature, pressure and level. Its universal analogue input accepts standard current and voltage signals (0–5 mA, 0–20 mA, 4–20 mA, 0–10 V, 0–75 mV and others). It also supports three-wire resistance thermometers and type K, L, J, S, B, T and A-1 thermocouples. Available control modes are ON/OFF, three-position, analogue PID, pulse PID and PWM PID. The unit can also serve as an alarm unit or a signal converter. Basic reduced error of measurement and of output signal generation is ≤ 0.2 %. It has one active analogue output and two discrete outputs (NPN transistor or relay). Inputs, outputs and supply circuits are galvanically isolated. Data exchange is via RS-485 using Modbus RTU. The housing mounts on a DIN rail, is rated IP30 and operates from -40 to +70 °C. Typical applications include power generation, metallurgy, and the chemical, food and other process industries.

Control type
ON/OFF, three-position, analogue PID, pulse PID, PWM PID
Number of independent controllers
one
Additional functions
alarm unit, converter
Analogue inputs
1

Technical specifications

Control typeON/OFF, three-position, analogue PID, pulse PID, PWM PID
Number of independent controllersone
Additional functionsalarm unit, converter
Analogue inputs1
Input typestandard passive; RTD — three-wire connection
Input sensors and signals0-5 mA, 0-20 mA, 4-20 mA, 0-2 V, 0-10 V, 0-75 mV, 0-200 mV, ТСМ 50М, ТСМ 100М, ТСП 50П, ТСП 100П, Pt100, ТХА (K), ТХК (L), ТЖК (J), ТПП 10 (S), ТПР (B), ТМКн (T), ТВР -1(A-1)
Measuring range-50…2500 °C
Basic reduced measurement error≤ 0.2 %
Discrete inputsnot fitted
Analogue output1, active
Output signal ranges0–5 mA / R ≤ 2000 Ω, 0–20 mA / R ≤ 500 Ω, 4–20 mA / R ≤ 500 Ω, 0–10 V / R ≤ 2 kΩ
Output signal generation error≤ 0.2 %
Discrete outputs2
Discrete output typesNPN transistor: up to 40 V, 100 mA; changeover relay: up to 230 V, 8 A
InterfaceRS-485
ProtocolModbus RTU
Displayseven-segment digital, four digits
Supply voltage230 V AC; 24 V DC
Power consumptionAC: max. 6.5 VA; DC: max. 180 mA
MountingDIN rail
Dimensions (HxWxD)94×106×58 mm
Weightmax. 0.35 kg
Ingress protectionIP30
Ambient temperature-40 °C to +70 °C
Panel versionUA, EN
StandardsДСТУ 2858-94, ДСТУ 2837-94, ГОСТ3044-94, DIN IEC 584-1, ДСТУ EN 60529:2014, ДСТУ IEC 60654-1:2001, ДСТУ IEC 60654-3:2001, ГОСТ 22261-94, ДСТУ 2887-94, ДСТУ 3272:2011, ДСТУ 2888-94, ДСТУ ГОСТ 2.610

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

The version is defined by the order code МІК-111Н-AA-C-D-U-L. AA is the input signal type (01–20) matching your sensor. C is the analogue output range (1–4: 0–5 mA, 0–20 mA, 4–20 mA or 0–10 V). D is the discrete output type: T (NPN transistor, up to 40 V, 100 mA) or P (relay, up to 230 V, 8 A). U is the supply: AC mains or 24 V DC. L is the panel language: UA or EN.

Similar products

Low-voltage equipment

Request a price and lead time

МІК-111Н — universal microprocessor PID controller. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.