Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

LOW-VOLTAGE EQUIPMENT

NH (LV) — low-voltage high breaking capacity fuses NH000–NH4a

NH000–NH4a blade fuses with a breaking capacity of up to 120 kA protect cable lines, motor circuits and transformers in LV networks. The rated voltage of the range is AC 400–1500 V, and the categories include gG, gTr, aM and gB. The fuse links are installed in switchboards, cable cabinets and transformer substations on the LV side.

Sizes
NH000, NH00, NH1, NH2, NH3, NH4a
Rated voltage
AC 400–1500 V (example: NH2 gG AC 500 V)
Breaking capacity
up to 120 kA
Categories
gG, gTr, aM, gB

Technical specifications

SizesNH000, NH00, NH1, NH2, NH3, NH4a
Rated voltageAC 400–1500 V (example: NH2 gG AC 500 V)
Breaking capacityup to 120 kA
CategoriesgG, gTr, aM, gB
Indicationcombined indicator (front and central)
Series example2055213: NH2 gG AC 500 V, 35–250 A
StandardsIEC 60269-1/-2, VDE 0636 parts 1, 2, 21; VDE 0670-402

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The fuse links are made in all standard sizes from NH000 to NH4a, and they have blade contacts. The current is limited already in the first half-cycle, and in the improved design the switching voltage is low, so power losses are minimal. The body is mechanically strong and the materials are corrosion-resistant. The combined operation indicator is visible both at the front and in the centre. The 2055213 series has size NH2, category gG, voltage AC 500 V and ratings of 35, 50, 63, 80, 100, 125, 160, 200, 224 and 250 A. The selectivity principle is simple. In case of a fault only the fuse link closest to the short-circuit location operates, and this can also be achieved in combination with circuit breakers when the characteristics are matched precisely. For transformers, selectivity between high-voltage and low-voltage fuse links is regulated by VDE 0670 part 402 (concepts A, B, C). The fuse links comply with IEC 60269-1/-2 and VDE 0636 parts 1, 2 and 21.

How to choose

The category is selected by the application. gG is full-range general-purpose protection, gTr is intended for transformers, aM protects motor circuits in a partial range, and gB is developed for the mining industry. The size depends on the current, and the NH000–NH4a range covers the path from compact fuse links to powerful incomers. For selectivity concepts with the high-voltage side, VDE 0670-402 distinguishes variants A, B and C, for example HH + NH gTr or HH + NH gG. Bases, barriers and handles for these fuse links are made by the NH-U range, and for semiconductors you need ULTRA rapid fast-acting fuses.

Request a price and lead time

NH (LV) — low-voltage high breaking capacity fuses NH000–NH4a. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the breaking capacity of NH000–NH4a fuses?

Up to 120 kA. The fuse links limit the short-circuit current already in the first half-cycle, so the cable and equipment behind them do not experience the full peak current.

How do the categories gG, gTr, aM and gB differ?

gG protects in the full general-purpose range, gTr is intended for transformers, aM protects motor circuits in a partial range, gB is developed for the mining industry.

What rated currents does the 2055213 series have?

It is NH2 of category gG at AC 500 V with ratings of 35, 50, 63, 80, 100, 125, 160, 200, 224 and 250 A and a combined indicator.

How is selectivity of LV fuse links with circuit breakers ensured?

It can be obtained with precise matching of the characteristics. Only the device closest to the short-circuit location operates, and for transformers VDE 0670 part 402 applies.

What voltages are NH fuse links made for?

The rated voltages of the range are AC 400–1500 V. For example, NH2 gG is rated for AC 500 V.

Similar products

Low-voltage equipment

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.