Arelos plastic distribution boards, flush-mounted and surface-mounted, 2–56 modules
Country: · Model: Arelos
The Arelos plastic distribution boards for 2–56 modules for DIN-rail equipment come flush-mounted, surface-mounted and for hollow walls HGW. The enclosures comply with UNE-EN 62208. They are installed in apartment, floor and office boards and in shops, during repair and reconstruction.
- Capacity
- 2 … 56 modules
- Mounting
- flush (PF) and surface (S)
- Versions
- with N/PE terminals (R1, R2), HGW versions for hollow walls, with ICT compartment
- Standard
- UNE-EN 62208
Technical specifications
| Capacity | 2 … 56 modules |
|---|---|
| Mounting | flush (PF) and surface (S) |
| Versions | with N/PE terminals (R1, R2), HGW versions for hollow walls, with ICT compartment |
| Standard | UNE-EN 62208 |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The flush-mounted models for brick and concrete walls are 8692 (2 modules), 8694 and 8208 (4), 5108 (8), 8688 (12), 5012 (14), 8685 (18), 8690 (22), 5250 (28), 8206 (40), 5260 (42) and 5270 (56). The surface-mounted equivalents are 8692S, 8684, 8209, 5109, 8703, 5021, 8704, 5281, 8216, 5261 and 5271. The index PF means a smoked door, the suffixes R1 and R2 one (earth) or two terminal bars, and a leading R film packaging. The models 5420, 5430 and 5440 have a separate sealable compartment, and there are also combined 5250ICT, 5260ICT, 5270ICT with an ICT compartment. In flush-mounted boards a partition prevents deformation of the enclosure during plastering, and it is removed after finishing. Boards for hollow walls are fixed with lugs COR5506/4, COR5260/4 or G-MP28/4, and the enclosures are joined with elements horizontally and vertically. Terminal bars of types A and B (106R, 108P, 112P, 212) are fitted in the standard slots. Spare doors, frames and module blanking plates 100 and TA1300 are available in ivory, white and grey.
How to choose
First determine the mounting: flush PF for brick and concrete walls, surface S, HGW for plasterboard. Then the number of modules, from 2 to 56. For a separate sealable compartment for devices with restricted access take 5420, 5430 or 5440, and if telecommunications are also needed, the ICT variants. For metal doors look at Metalbox for 14–56 modules.
Request a price and lead time
Arelos plastic distribution boards, flush-mounted and surface-mounted, 2–56 modules. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
Which Arelos models are flush-mounted for 4, 8 and 12 modules?
8694 and 8208 for 4 modules, 5108 for 8, 8688 for 12.
What do the indexes PF, R1 and R2 mean?
PF means a smoked door, R1 one earth terminal bar, R2 two terminal bars, and a leading R film packaging.
Are there Arelos boards for plasterboard walls?
Yes, the HGW versions are fixed with lugs COR5506/4, COR5260/4 or G-MP28/4.
Why is there a partition in a flush-mounted board?
It prevents deformation of the enclosure during plastering, and it is removed after finishing.
Which standard describes the Arelos enclosures?
UNE-EN 62208 on empty enclosures for low-voltage switchgear and controlgear assemblies.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.