ПР-8-24, ПР-8-110, ПР-8-220 — pulse relays for flashing signalling
Country: Ukraine · Model: ПР-8-24, ПР-8-110, ПР-8-220
supply 24–220 V · load current 0.003–8 A · on–pause cycle 0.4–1 s · consumption 0.05 W
The ПР-8 series pulse relay produces a flashing (intermittent) signal in the electrical signalling and automation circuits of industrial facilities. The device has two input contacts and needs no separate supply: one terminal is connected to the power bus, the other acts as the flashing bus, and the load is connected in series with the relay. It can be connected to the positive or negative bus, to the phase or to neutral. The relay operates at supply voltages from 24 to 220 V AC or DC and load currents from 0.003 to 8 A, with an on–pause cycle of 0.4 to 1 s. Power consumption in operation is only 0.05 W, and its own current during the pause is 0.0003 A. It withstands a surge overload current of 60 A for 20 ms, has a built-in operation indicator and is suited to LED signal fittings. It replaces power interrupters ППБ-1…ППБ-4, ППБР-1, ППБР-2, ППБР-2С and РСВ 18-31, including at nuclear and thermal power stations.
- Supply voltage
- 24 to 220 V, AC or DC
- Load current range
- 0.003 to 8 A
- Power consumption in operation
- 0.05 W
- Own current draw during pause
- 0.0003 A
Technical specifications
| Supply voltage | 24 to 220 V, AC or DC |
|---|---|
| Load current range | 0.003 to 8 A |
| Power consumption in operation | 0.05 W |
| Own current draw during pause | 0.0003 A |
| Surge overload current | 60 A for 20 ms |
| On–pause cycle | 0.4 to 1 s |
| Temperature range | −15 to +40 °C |
| Input contacts | 2 |
| Connection | one terminal to the power bus, the other as the flashing bus; load in series with the relay; to +, −, phase or neutral |
| Indication | built-in operation indicator |
| Versions | ПР-8-24 (24 V), ПР-8-110 (110 V), ПР-8-220 (220 V), ПР-8-110п and ПР-8-220п (AC) |
| AC versions | phase–neutral connection; switching at voltage zero crossing |
| Compatibility | LED signal fittings |
| Replaces | ППБ-1…ППБ-4, ППБР-1, ППБР-2, ППБР-2С, РСВ 18-31 |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
Select the version by the signalling circuit voltage: ПР-8-24 for 24 V, ПР-8-110 for 110 V, ПР-8-220 for 220 V. For AC circuits use ПР-8-110п or ПР-8-220п. These are connected phase to neutral and switch on and off at the voltage zero crossing.
Similar products
Request a price and lead time
ПР-8-24, ПР-8-110, ПР-8-220 — pulse relays for flashing signalling. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.