Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

LOW-VOLTAGE EQUIPMENT

RIO-5N-DI8-DO8 — combined discrete input/output module

8 DI / 8 DO · RS-485, Modbus RTU · 24 V DC or 220 V AC supply · up to 32 devices per segment, line up to 1200 m

RIO-5N-DI8-DO8 is a combined remote I/O module that houses 8 discrete inputs and 8 discrete outputs in a single enclosure. It reads the states of sensors and switches actuators on command from a controller or PC, communicating over an RS-485 interface using the Modbus RTU protocol. Logic 0 at the input corresponds to 0-7 V and logic 1 to 18-30 V. Input current is no more than 10 mA, and the maximum pulse frequency is 5 Hz. Outputs are available as transistor (≤ 40 V, ≤ 100 mA), mechanical relay (220 V AC, ≤ 5 A resistive) or solid-state relay (60 V, ≤ 600 mA) types. Galvanic isolation is at least 500 V, or at least 1500 V for relay outputs. Up to 32 devices can share one network segment, with a line length of up to 1200 metres. The IP20 housing mounts on a DIN rail. The module is used to build distributed monitoring and control systems for process equipment.

Number of discrete inputs
8
Number of discrete outputs
8
Maximum pulse frequency
5 Hz
Input current
≤10 mA

Technical specifications

Number of discrete inputs8
Number of discrete outputs8
Maximum pulse frequency5 Hz
Input current≤10 mA
Logic 0 input signal0-7 V
Logic 1 input signal18-30 V
Transistor output: voltage / current≤ 40 V / ≤ 100 mA
Relay output AC: voltage220 V
Relay output AC: current (resistive / inductive load)≤ 5 A / ≤ 3 A
Relay output DC: voltage5 V to 30 V
Relay output DC: current (resistive load)10 mA to 5 A
Solid-state relay: voltage / current60 V / ≤ 600 mA
DC supply voltage24 V (10 V to 36 V)
AC supply voltage220 V (110 V to 242 V)
Consumption, DC supplyno more than 130 mA
Power consumption, AC supplyno more than 5.5 W
Built-in power source24 V, ≤ 80 mA
Galvanic isolation voltageat least 500 V
Galvanic isolation voltage, relay outputsat least 1500 V
Interface / protocolRS-485 / Modbus RTU
Devices per network segmentup to 32
Maximum line lengthup to 1200 metres
Network address range255
MountingDIN rail
Ingress protectionIP20
Dimensions132x128x57 mm
Weight< 0.18 kg
Operating temperature-40 °C to 70 °C
Humidity30 to 80% non-condensing
Atmospheric pressure84 to 106.7 kPa
Environmental groupsС3, B3
Mean time to failureat least 100 000 hours
Mean service lifeat least 10 years
StandardsДСТУ IEC 60654-1:2001, ДСТУ IEC 60654-3:2001, ДСТУ 61326-1

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

Choose the output type to suit the load. Transistor outputs (≤ 40 V, ≤ 100 mA) suit low-current DC circuits. Mechanical relays (220 V AC up to 5 A, 5–30 V DC) handle power loads and AC circuits. Solid-state relays (60 V, ≤ 600 mA) suit frequent contactless switching. The supply can be 24 V DC (10–36 V) or 220 V AC (110–242 V).

Similar products

Low-voltage equipment

Request a price and lead time

RIO-5N-DI8-DO8 — combined discrete input/output module. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.