MultiNET_ATS — static transfer switches 16–600 A
Country: France · Model: MultiNET_ATS
The MultiNET_ATS static switches of 16–600 A power a load from two independent sources, for example two UPS units, and transfer it to the backup within milliseconds. They are installed in server rooms and data centers for single-supply consumers, and also as an external UPS bypass.
- Current
- 16/32 A, 32/63/120 A (19 inch), 50–600 A
- Transfer time
- 8–12 ms (16/32 A); ≤ 4 ms synchronous / ≤ 10 ms asynchronous sources
- Efficiency
- 99 %
- Standard
- EN 62310-2
Technical specifications
| Current | 16/32 A, 32/63/120 A (19 inch), 50–600 A |
|---|---|
| Transfer time | 8–12 ms (16/32 A); ≤ 4 ms synchronous / ≤ 10 ms asynchronous sources |
| Efficiency | 99 % |
| Standard | EN 62310-2 |
| Functions | priority source selection, manual bypass, event log |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The range consists of three groups: compact 16/32 A units, 32, 63 and 120 A models in a case for a 19-inch rack, and cabinet-type 50–600 A units. The smaller models transfer in 8–12 ms, the larger ones in 4 ms or less with synchronous sources and up to 10 ms with asynchronous ones. Efficiency is 99 %, so the switch adds almost no losses to the circuit. The user sets the priority source, the manual bypass allows the device to be serviced without de-energizing, and the event log records all transfers for fault analysis. The switches comply with EN 62310-2.
How to choose
The rating is chosen by the load current, and the group by the mounting place: in a rack or in a separate cabinet. For server power supplies the transfer time is decisive, so the sources should preferably be synchronized to keep the larger models within 4 ms. A pair of online UPS units, for example HELIOS-TH or IRIS+TT, is often used as the two sources for dual supply.
Request a price and lead time
MultiNET_ATS — static transfer switches 16–600 A. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What is the transfer time of the MultiNET_ATS static switch?
From 8 to 12 ms in the 16/32 A models, and in the larger ones up to 4 ms with synchronous and up to 10 ms with asynchronous sources.
Can MultiNET_ATS be used as an external UPS bypass?
Yes, the switch is connected to the UPS output and to the mains, and it transfers the load to the bypass line while the UPS is being repaired.
What current ratings does MultiNET_ATS have?
16/32 A, 32/63/120 A in the 19-inch rack version, and cabinet-type units from 50 to 600 A.
Which standard do the MultiNET_ATS switches comply with?
They comply with EN 62310-2 for static transfer systems, and efficiency is 99 %.