MultiGuard / SpikeGuard / CommsGuard / PureAC — surge protection power filters

Power filters and adapters for currents up to 16 A for household and office electronics. They suppress surges, voltage spikes and radio-frequency noise that reach PCs, TVs, routers and telephones through the mains and the telephone line.

Current
up to 13 A (UK) / 16 A (Schuko)
Protection class
Class III
Versions
extension leads with 4–6 sockets, with USB, with a switch; adapters SpikeGuard, CommsGuard (with RJ11 protection), PureAC (RFI filter 3/7/13 A)
CommsGuard
160 J, 6.5 kA (8/20 μs)

Technical specifications

Currentup to 13 A (UK) / 16 A (Schuko)
Protection classClass III
Versionsextension leads with 4–6 sockets, with USB, with a switch; adapters SpikeGuard, CommsGuard (with RJ11 protection), PureAC (RFI filter 3/7/13 A)
CommsGuard160 J, 6.5 kA (8/20 μs)

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The range consists of MultiGuard extension leads with 4–6 sockets, including ones with USB ports for charging and with a switch, as well as plug-in adapters. Versions for the UK plug are rated for 13 A, and for Schuko 16 A. Surge protection is built to Class III, that is, it is the final level right at the consumer, complementing the surge arrester in the panel. SpikeGuard restrains surges in a single socket, CommsGuard additionally protects the telephone line through an RJ11 connector and absorbs 160 J at a discharge current of 6.5 kA with an 8/20 μs waveform. PureAC contains an RFI filter of 3, 7 or 13 A and removes high-frequency noise that disturbs audio and measuring equipment.

How to choose

First decide on the socket standard, since the 13 or 16 A rating depends on it. For a workplace with several appliances take a MultiGuard extension lead; for a single device an adapter is enough. If a telephone line or DSL comes into the equipment, CommsGuard is needed, and for sensitive audio PureAC. Such filters do not protect against lightning surges at the building input; there DSP surge arresters of type 1 and 2 with Imax of 20–240 kA are installed.

Request a price and lead time

MultiGuard / SpikeGuard / CommsGuard / PureAC — surge protection power filters. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How much energy does the CommsGuard adapter absorb?

CommsGuard dissipates 160 J and withstands a discharge current of 6.5 kA of an 8/20 μs pulse, protecting both the power and the RJ11 line.

What current is the MultiGuard extension lead rated for?

The version with a UK plug carries up to 13 A, and with a Schuko plug up to 16 A.

Does a Class III power filter replace the surge arrester in the panel?

No, Class III protects only the end consumer. At the input a type 1 or 2 surge arrester is needed, for example the DSP series with Imax from 20 kA.

What ratings does the PureAC RFI filter have?

PureAC is made for 3, 7 and 13 A, and the rating is chosen by the current of the appliance connected to the adapter.

How many sockets do the MultiGuard extension leads have?

The extension leads have 4–6 sockets, and there are versions with USB ports for charging and with a switch.

Similar products

Low-voltage equipment

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.