ITT dry low-voltage isolation transformers 1–1600 kVA

Dry low-voltage isolation transformers rated 1–350 kVA in single-phase and 3–1600 kVA in three-phase versions. Input and output voltage lies within 110–960 V, 50/60 Hz. They are built to the customer’s requirements for data centres, power plants and industrial sites.

Power
1 phase 1–350 kVA; 3 phases 3–1600 kVA
Voltage
input and output 110–960 V, 50/60 Hz
K-factor
4, 9, 13, 20, 25, 50
Windings
aluminium or copper

Technical specifications

Power1 phase 1–350 kVA; 3 phases 3–1600 kVA
Voltageinput and output 110–960 V, 50/60 Hz
K-factor4, 9, 13, 20, 25, 50
Windingsaluminium or copper
Thermal classF, H, 200 °C
Degree of protectionIP21 or IP31 (IP54 optional)
Optionsanti-seismic and medical versions

Replacement for

TSZI, TSZ 0.38/0.23 kV (dry low-voltage), OSM1-0.063…4 kVA (single-phase), OSO

selected by purpose and main parameters, please confirm with the manager

Replacement pages: ОСМ1-0,063, ОСМ1

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The series covers single-phase, three-phase and three-single-phase transformers. Windings are made of aluminium or copper, so the material is chosen to suit the size limits of a given order. Thermal class F, H or 200 °C sets the permissible winding temperature, and with it the load margin in a hot room. The K-factor of 4, 9, 13, 20, 25 or 50 shows how large a share of harmonics in the load current, for example from rectifiers and UPS units, the transformer can stand. Standard protection is IP21 or IP31, with IP54 as an option. Anti-seismic and medical versions are also available.

How to choose

First fix the power and the number of phases. Single-phase models go up to 350 kVA and three-phase ones run from 3 to 1600 kVA. Then pick the K-factor from the harmonic content of the load and the winding material. Where better protection against dust and splashes is needed, order IP54 instead of IP21 or IP31. For telecom sites that need high attenuation of interference there is a separate IT series (RS, ARM, ARM2).

Request a price and lead time

ITT dry low-voltage isolation transformers 1–1600 kVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What power range do the ITT isolation transformers cover?

Single-phase transformers are made for 1–350 kVA and three-phase ones for 3–1600 kVA. The exact rating is chosen for the site.

What input and output voltage do the ITT transformers have?

Input and output are made within 110–960 V at 50/60 Hz. The voltage is set to the customer’s requirements.

What does the K-factor mean for ITT transformers?

The K-factor shows tolerance to load harmonics. Values 4, 9, 13, 20, 25 and 50 are available, and the higher the number, the more harmonics are acceptable.

What protection degree and thermal class does the ITT have?

The protection degree is IP21 or IP31, with IP54 as an option. Thermal class is F, H or 200 °C.

What are the ITT windings made of and are there special versions?

Windings are either aluminium or copper. For special conditions, anti-seismic and medical versions are offered.

Similar products

Power transformers

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.