Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

POWER TRANSFORMERS

GI 3600 / Isotransformer 2000 — isolation transformer, 2–3.6 kVA

An isolation transformer rated 2.0 or 3.6 kVA that galvanically separates a vessel from shore power. It breaks the electrical link between the hull and shore earth and protects the underwater parts from galvanic corrosion.

Power
2.0 kVA (toroidal) and 3.6 kVA
Voltage
230/110 V or 240/120 V
Frequency
50/60 Hz
Soft start
built in

Technical specifications

Power2.0 kVA (toroidal) and 3.6 kVA
Voltage230/110 V or 240/120 V
Frequency50/60 Hz
Soft startbuilt in
Insulation classH (180 °C), GI 3600
Windingscopper
Customs codes (for reference)
HS code8504.32
UKTZED code (Ukraine)8504320090 (dry 1–16 kVA)
CN code (EU)85043200 (dry 1–16 kVA)

Replacement for

isolating OSM1, TSZI; OSM1-2.5…4 kVA; no specialised analogue for ship shore power

selected by purpose and main parameters, please confirm with the manager

Replacement pages: ОСМ1-2,5, ОСМ1

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The Isotransformer 2000 is built on a toroidal core and rated 2.0 kVA. The GI 3600 delivers 3.6 kVA and has class H insulation (180 °C). The windings are copper, the circuit switches between 230/110 V and 240/120 V, and frequency is 50/60 Hz, so the vessel can plug into both European and American pedestals. A built-in soft start limits the magnetizing inrush at switch-on, so the breaker on the shore pedestal does not trip. Without isolation the hull is tied through the shore protective conductor to neighboring boats and dock metalwork, and galvanic currents flow between them. Downstream of the transformer the onboard neutral and protective conductor are bonded to the hull, and the shore PE is not connected to it.

How to choose

Choose the rating by the load the vessel draws from shore, 2.0 kVA is enough for light consumption, while charging banks and running domestic appliances calls for the GI 3600 at 3.6 kVA. The 230/110 V or 240/120 V switch position is set to match the marina supply and the onboard network. If a WPC inverter-charger sits downstream of the transformer, its charging input current counts in the total load.

Request a price and lead time

GI 3600 / Isotransformer 2000 — isolation transformer, 2–3.6 kVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the rating of the GI 3600 isolation transformer?

The GI 3600 is rated 3.6 kVA, the Isotransformer 2000 is rated 2.0 kVA.

What insulation class does the GI 3600 have?

Class H, 180 °C.

What voltages does the marine isolation transformer switch between?

Between 230/110 V and 240/120 V at 50/60 Hz.

Why does a boat need an isolation transformer?

It breaks the link between hull and shore earth, so galvanic currents between boats and the dock do not eat away the underwater parts.

Why does the GI 3600 not trip the pedestal breaker at switch-on?

The built-in soft start limits the magnetizing inrush that a 3.6 kVA transformer would otherwise put on the shore breaker.

Similar products

Power transformers

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.