Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

POWER TRANSFORMERS

IT / IT M — dry transformers and LV autotransformers

The manufacturer has made the dry low-voltage transformers IT and the control transformers IT M for more than 50 years, including as components for its own UPS and stabilizers. The range covers isolating and autotransformer schemes in single-phase and three-phase versions.

Type
isolating transformers and autotransformers, 1 and 3 phases
Insulation
windings impregnated with class H resin
IT M
single-phase control transformers (models IT M-25 … IT M-500) with double/triple primary voltage

Technical specifications

Typeisolating transformers and autotransformers, 1 and 3 phases
Insulationwindings impregnated with class H resin
IT Msingle-phase control transformers (models IT M-25 … IT M-500) with double/triple primary voltage

Replacement for

TSZI, TSZ 0.38/0.23 kV (dry low-voltage), OSM1-0.063…4 kVA (single-phase), OSO

selected by purpose and main parameters, please confirm with the manager

Replacement pages: ОСМ1-0,063, ОСМ1

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The windings are impregnated with resin of heat class H, and the transformer works without oil, so it is installed in rooms and electrical cabinets without the measures that oil-filled equipment requires. An isolating transformer galvanically separates the load from the mains, which is needed for measuring circuits, medical rooms and systems with an isolated neutral. An autotransformer is lighter at the same rating and suits cases when only the voltage levels need to be matched, for example for imported equipment. The IT M series consists of single-phase control transformers from IT M-25 to IT M-500. The primary winding is designed for two or three voltages, so one transformer is connected to different networks, and the secondary feeds contactor coils, relays and automation circuits.

How to choose

The task determines the scheme type. For galvanic isolation take an isolating IT, and for changing the voltage level without isolation an autotransformer. For control circuits in an electrical cabinet the IT M is selected by the total power of coils and signal lamps in the range from IT M-25 to IT M-500. When the voltage must be changed smoothly during operation, an adjustable toroidal ARC with a manual or servo drive is required.

Request a price and lead time

IT / IT M — dry transformers and LV autotransformers. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What insulation class do the IT transformers have?

The windings are impregnated with class H resin, and the transformers are dry, without oil, and suitable for installation indoors.

What is IT M in the transformer range?

Single-phase control transformers, models from IT M-25 to IT M-500, with double or triple primary voltage.

Are the IT transformers made in a three-phase version?

Yes, the IT isolating transformers and autotransformers are made for 1 and 3 phases.

How long has the manufacturer been making dry transformers?

For more than 50 years. The same transformers are used in the manufacturer's own UPS and stabilizers.

Similar products

Power transformers

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.