Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

POWER TRANSFORMERS

BT / BT HC — epoxy LV bushings 1–3 kV, 250–8000 A (EN 50387)

BT and BT HC are cast epoxy low-voltage bushings for bringing out the LV windings of transformers, for rated currents from 250 to 8000 A. They work on oil-filled, gas-insulated and dry-type transformers per EN 50387.

Rated voltage
1 kV (BT); 1–3 kV (BT HC)
Rated current
BT: 250, 1600, 2000, 2500 A; BT HC: 4000–8000 A
Standard
EN 50387
Material
cast epoxy resin, monoblock

Technical specifications

Rated voltage1 kV (BT); 1–3 kV (BT HC)
Rated currentBT: 250, 1600, 2000, 2500 A; BT HC: 4000–8000 A
StandardEN 50387
Materialcast epoxy resin, monoblock
Applicationoil-filled, gas-insulated and dry-type transformers

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Compared with porcelain, epoxy insulation is lighter, more durable and less brittle. The bushing is cast as a single piece, no assembly is needed, so storage and installation are simpler. The basic BT is rated for 1 kV and is made for 250, 1600, 2000 and 2500 A. The EN 50387 standard defines the connection dimensions of LV bushings. The high-current BT HC (High Current) for 1–3 kV covers 4000–8000 A and is intended for powerful transformers, for example auxiliary, rectifier and furnace units. In the general catalog of epoxy bushings the range is given as 1–42 kV and 250–8000 A, where the lower part falls to BT and BT HC. The products are compatible with IEC standards and homologated by ENEL, a spare parts catalog is available, and original spare parts are supplied within 72 hours. Applications include 6–35/0.4 kV distribution transformers, dry-type transformers for buildings and industrial sites, traction transformers, new machines and repair. Detailed drawings are collected in a separate catalog PPS-PPQ-BT.

How to choose

The LV-side current splits the range in half. Up to 2500 A the BT at 1 kV is taken, and from 4000 to 8000 A the BT HC at 1–3 kV is needed. If the machine already has a porcelain bushing per DIN 42530 or EN 50386 and the replacement must be in the same dimensions, see the porcelain bushings for 250–6500 A.

Request a price and lead time

BT / BT HC — epoxy LV bushings 1–3 kV, 250–8000 A (EN 50387). We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What currents are BT and BT HC made for?

BT for 250, 1600, 2000 and 2500 A, and BT HC for 4000–8000 A.

Which standard defines the dimensions of BT bushings?

EN 50387, which sets the connection dimensions of LV bushings for transformers.

Can BT be installed on dry-type transformers?

Yes, the bushings are used on oil-filled, gas-insulated and dry-type transformers.

How quickly are original spare parts supplied?

Within 72 hours, and there is a separate spare parts catalog.

Similar products

Power transformers

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.