High-voltage transformers 80–150 kV and HV isolating transformers up to 140 kV DC

High-voltage transformers rated 80–150 kV with air or oil insulation, designed for a given voltage and set of dimensions. HV isolating transformers are built separately, with the secondary circuit insulated from earth up to 140 kV DC. They are used in test installations, water treatment and other systems.

Rated voltage
80–150 kV
Isolating transformers
secondary circuit insulated from earth up to 140 kV DC
Insulation
air or oil
Application
test installations, water treatment, etc.

Technical specifications

Rated voltage80–150 kV
Isolating transformerssecondary circuit insulated from earth up to 140 kV DC
Insulationair or oil
Applicationtest installations, water treatment, etc.

Replacement for

test IOM-100/25, IOM-100/100 (general type); isolating HV up to 140 kV DC — no direct analogue

selected by purpose and main parameters, please confirm with the manager

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The design is worked out for each task, so voltage and dimensions are fixed at the project stage rather than taken from a standard range. Development experience with such transformers exceeds 60 years. The type of insulation, air or oil, is chosen together with the voltage and the size limits. The isolating version separates the secondary circuit from earth, so a load sitting at a high potential relative to earth can be connected to it, with insulation reaching 140 kV DC. These transformers are installed in test installations and water treatment systems, and the full list of uses depends on the project.

How to choose

The choice comes down to the rated voltage within 80–150 kV and the type of insulation. Insulation type affects the size of the unit, so size limits are best stated up front. If the secondary circuit must be separated from earth, take the isolating version with insulation up to 140 kV DC. For low-voltage tasks, look at the power, control and special transformers of 50 VA – 500 kVA, and for smooth voltage adjustment at the Regavolt autotransformers with an output of 0–100% or 0–115% of the input.

Request a price and lead time

High-voltage transformers 80–150 kV and HV isolating transformers up to 140 kV DC. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What voltage are the high-voltage transformers of this series made for?

The rated voltage is 80–150 kV. The exact voltage and dimensions are set for the project.

What insulation do these high-voltage transformers have?

They come with air or oil insulation. The choice depends on the voltage and the dimensions.

What is an HV isolating transformer rated up to 140 kV DC?

It is a transformer whose secondary circuit is insulated from earth up to 140 kV DC. It is needed where the load sits at a high potential relative to earth.

Where are such transformers used?

In test installations, water treatment systems and other projects. The list depends on the customer's task.

Can a transformer be ordered to fit given dimensions?

Yes, they are designed for a given voltage and dimensions. Development experience exceeds 60 years.

Similar products

Power transformers

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.