Setavolt mSA / mSA-3 — motorised variable autotransformers 3–200 A

The Setavolt mSA (single-phase, 3–100 A) and mSA-3 (three-phase, 10–200 A) motorised autotransformers change voltage smoothly from zero to 117 % of the input. The electric drive makes regulation remote, so the series is taken for building into OEM equipment and for laboratory benches.

Current
mSA (1 phase) 3–100 A, mSA-3 (3 phases) 10–200 A
Output voltage
0–117 % of the input
mSA-3 grid
400 V (HB), 208 V (LB), 480 V (HB-480)
mSA-3 version
IP20 on wheels, digital voltmeter and ammeter, input circuit breaker

Technical specifications

CurrentmSA (1 phase) 3–100 A, mSA-3 (3 phases) 10–200 A
Output voltage0–117 % of the input
mSA-3 grid400 V (HB), 208 V (LB), 480 V (HB-480)
mSA-3 versionIP20 on wheels, digital voltmeter and ammeter, input circuit breaker
mSA versionopen assembly for OEM

Replacement for

LATR-1M, LATR-2M, RNO-250-2, RNO-250-5, RNO-250-10, RNT (voltage regulators)

selected by purpose and main parameters, please confirm with the manager

Replacement pages: ЛАТР-1М, ЛАТР-2М, ЛАТР, РНО-250, РНО

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

An electric motor turns the regulating assembly, so voltage is set from a console or a control system and not by hand at the unit. The single-phase mSA is supplied as an open assembly without a cover and is mounted inside the cabinet or machine of the equipment manufacturer. The three-phase mSA-3 is made as a separate mobile unit in an IP20 enclosure on wheels. A digital voltmeter and ammeter are on the front panel and a circuit breaker is installed at the input, so a separate protective panel is not needed for it. For the mSA-3 there are three grid options: HB for the European three-phase grid, LB for 208 V and HB-480 for 480 V.

How to choose

First determine the number of phases and the load current. The mSA for 3–100 A suits building into a machine, and the mSA-3 for 10–200 A with its own instruments is more convenient for a laboratory or workshop. When more than 200 A is needed, move to the induction Setavolt iSA for 150–800 A, and without an electric drive the manual SA series for 3–100 A will do.

Request a price and lead time

Setavolt mSA / mSA-3 — motorised variable autotransformers 3–200 A. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Up to what voltage does the mSA autotransformer regulate?

The output changes from 0 to 117 % of the input voltage, so the unit can raise the voltage slightly above the mains.

What is the difference between mSA and mSA-3?

The mSA is single-phase, 3–100 A, in an open version for OEM. The mSA-3 is three-phase, 10–200 A, in an IP20 enclosure on wheels with a voltmeter, ammeter and input circuit breaker.

What grid is the three-phase mSA-3 designed for?

There is an HB version for the European three-phase grid, LB for 208 V and HB-480 for 480 V, and the letter is chosen by the supply voltage.

Can the mSA be built into your own equipment?

Yes, the single-phase mSA is supplied as an open assembly precisely for building into OEM equipment, and the electric drive is connected to the machine's control system.

Similar products

Power transformers

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.