Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

POWER TRANSFORMERS

CT20–CT90 / CT20N / CT50 / CT60II / CT80II — 0.4 kV current transformers

The CT20–CT90, CT20N, CT50, CT60II and CT80II measuring current transformers for 0.4 kV networks have a 5 A secondary current and a primary current up to 3200 A. They work in metering points and protection circuits of low-voltage switchboards, and the split-core and outdoor versions are designed for remote metering systems.

Primary current
up to 3200 A (CT20–90), up to 1800 A (CT80II)
Secondary current
5 A
Versions
busbar and cable, split-core (CT80II ABR), outdoor (CT60II EXT)
Standards
IEC 60044-1, BS 2627

Technical specifications

Primary currentup to 3200 A (CT20–90), up to 1800 A (CT80II)
Secondary current5 A
Versionsbusbar and cable, split-core (CT80II ABR), outdoor (CT60II EXT)
StandardsIEC 60044-1, BS 2627

Replacement for

T-0.66, TShP-0.66, TOP-0.66, TShL-0.66, TNSh-0.66 (current transformers 0.66 kV, 5–5000 A)

selected by purpose and main parameters, please confirm with the manager

Replacement pages: ТНШ-0,66, ТНШ, ТОП-0,66, ТОП, ТШП-0,66, ТШП

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The main CT20–CT90 range consists of busbar and cable transformers for a primary current up to 3200 A. Busbar types are slipped onto the switchboard bus, cable types are put over the cable, and in both cases the conductor itself serves as the primary winding. The CT80II in the split-core ABR version is rated for a current up to 1800 A; its core opens, so the transformer is mounted on a live line without disconnecting the cable or bus. The CT60II EXT is an outdoor version and is installed outside the switchgear room, at remote metering points. The 5 A secondary current of all models matches the standard input of meters, network analyzers and overcurrent protection relays. The transformers are made to the international IEC 60044-1 and the British BS 2627.

How to choose

First find out the line current and the mounting method. For a new switchboard with busbars or cable for a current up to 3200 A, the model is taken from the CT20–CT90 range to suit the conductor size, and for upgrading a live line the split-core CT80II ABR up to 1800 A is more convenient. If the transformer will stand outdoors, at a remote metering point, the CT60II EXT version is needed. The CT20N and CT50 models belong to the same range; the exact size is chosen by the window for the bus or cable and by the primary current.

Request a price and lead time

CT20–CT90 / CT20N / CT50 / CT60II / CT80II — 0.4 kV current transformers. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the secondary current of the CT20–CT90 current transformers?

The secondary current is 5 A, so they are connected to meters, network analyzers and relays with a 5 A current input.

What primary current is the split-core CT80II ABR rated for?

Up to 1800 A. Its core opens, so the transformer is placed on a live cable or bus without dismantling.

Can a 0.4 kV current transformer be installed outdoors?

The CT60II EXT version is intended for outdoor installation, and it is used in remote metering systems.

Which standards do the CT20–CT90 current transformers comply with?

They are made to IEC 60044-1 and the British standard BS 2627 and have a 5 A secondary current.

Up to what primary current can a transformer be selected from the CT20–CT90 range?

The range goes up to 3200 A, and the models are busbar and cable types. For currents up to 1800 A there is the split-core CT80II.

Similar products

Power transformers

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.