Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

POWER TRANSFORMERS

Low-voltage current and voltage transformers 600/720 V

The line of low-voltage current and voltage transformers of the 600/720 V class is intended for commercial metering, switchboards and low-voltage switchgear. The 600 V voltage transformers come in single- and three-phase versions rated 40–750 VA, and the current side covers indoor, bushing-type and wide-range CTs.

Voltage
600/720 V
Types
indoor CTs, bushing CTs, wide-range Encompass and RevenueSense CTs, 600 V VTs
600 V VTs
single- and three-phase, with and without fuses, 40–750 VA
Standards
IEEE C57.13; UL/cUL, CSA

Technical specifications

Voltage600/720 V
Typesindoor CTs, bushing CTs, wide-range Encompass and RevenueSense CTs, 600 V VTs
600 V VTssingle- and three-phase, with and without fuses, 40–750 VA
StandardsIEEE C57.13; UL/cUL, CSA

Replacement for

T-0.66, TShP-0.66, TOP-0.66, TShL-0.66, TNSh-0.66 (current transformers 0.66 kV, 5–5000 A); NOS-0.5, NTS-0.5 (voltage transformers up to 0.5 kV)

selected by purpose and main parameters, please confirm with the manager

Replacement pages: НОС-0,5, НОС, НТС-0,5, НТС, ТНШ-0,66, ТНШ, ТОП-0,66, ТОП, ТШП-0,66, ТШП

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Indoor current transformers are installed in LV switchboards and cells where a bus or a cable passed through the window serves as the primary conductor. Bushing-type CTs are fitted over the bushing of a device, so no separate space in the cabinet is needed for them. Wide-range CTs of the Encompass and RevenueSense series are designed for commercial metering where the load varies greatly during the day, and one size covers both small and rated currents. The 600 V voltage transformers are made with built-in fuses or without them, so primary circuit protection can be taken from the VT itself or moved to a separate block. The units are built to IEEE C57.13 with UL/cUL and CSA certification, which is required for switchboards under North American codes.

How to choose

First determine what has to be measured, current or voltage. For buses or cable in a switchboard, take an indoor CT; for a device bushing, a bushing-type; and for commercial metering with a strongly varying load, a wide-range Encompass or RevenueSense. The 600 V voltage transformer is selected by the number of phases and the power within 40–750 VA, adding up the consumption of all connected instruments with a margin. Power for control circuits in the same switchgear is taken from separate control transformers of the same line.

Request a price and lead time

Low-voltage current and voltage transformers 600/720 V. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What power do the 600 V voltage transformers have?

From 40 to 750 VA, in single-phase or three-phase versions, with or without fuses.

What does the wide-range Encompass current transformer give for metering?

It holds accuracy over a wide range of primary current, so one unit correctly counts both small and rated loads. The RevenueSense series solves a similar task.

Which standards are these current and voltage transformers made to?

To IEEE C57.13, with UL/cUL and CSA certification for the North American market.

What voltage are the current transformers of this line rated for?

For the 600/720 V class, that is, with a margin for low-voltage switchboards and switchgear.

Where is a bushing-type current transformer installed?

On the bushing of a circuit breaker or power transformer. The bushing itself then serves as the primary conductor, and the transformer takes no space in the cell.

Similar products

Power transformers

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.