Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

POWER TRANSFORMERS

ET3SM — Marine LV Transformers in an IP23 Enclosure (400–1 600 kVA)

Three-phase marine transformers ET3SM with a power from 400 to 1 600 kVA in a steel IP23 enclosure for control and lighting circuits on ships and offshore installations. Voltage up to 1 000 V, frequency 50 Hz, insulation class H (180 °C) or F (155 °C). The C2/E1 version is designed for humidity, vibration and salty air.

Model range
ET3SM-400, -500, -630, -800, -1000, -1250, -1600
Voltage
up to 1 000 V
Frequency
50 Hz
Insulation class
H (180 °C) or F (155 °C)

Technical specifications

Model rangeET3SM-400, -500, -630, -800, -1000, -1250, -1600
Voltageup to 1 000 V
Frequency50 Hz
Insulation classH (180 °C) or F (155 °C)
ClimateC2/E1 (marine), 45 °C
Degree of protectionIP23, steel enclosure, RAL 7035
Terminalsclamps 10–240 mm² or copper busbars
CoolingAN
Standards and registersEN/IEC 60726, EN/IEC 61558; GL, PRS, RMRS, RINA, LR, BV, DNV, ABS, NATO

Replacement for

marine dry TSZM (general type), TSZ 0.4 kV 400–1600 kVA — made to special order

selected by purpose and main parameters, please confirm with the manager

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The model range covers ET3SM-400, -500, -630, -800, -1000, -1250 and -1600, with the number in the designation corresponding to the power in kVA. The enclosure is quickly disassembled to reach the winding taps and adjust the parameters. Cables are brought in through the floor, which orders the installation and additionally protects the entries mechanically. The enclosure is painted with powder paint RAL 7035, or another colour at the customer's wish. Terminals are made as clamps with a cross-section of 10–240 mm² or copper busbars, cooling is natural air AN, and the working position is vertical. Made to EN/IEC 60726 and EN/IEC 61558, and depending on the order to the rules of GL, PRS, RMRS, RINA, LR, BV, DNV, ABS and NATO. The factory has kept a reference list of marine deliveries since 1994. The ambient temperature is 45 °C.

How to choose

The power is chosen from the series 400, 500, 630, 800, 1000, 1250 or 1600 kVA according to the total load of the circuits. Insulation class H (180 °C) or F (155 °C) determines the thermal margin, and it is agreed with the project and the ship's register. For repair crews, safety transformers ET3oM are made, and for thruster devices the starting autotransformers EA3RM-Compact. For land installations with circuit isolation see ET1MED, and for railway cabinets ET3KOL.

Request a price and lead time

ET3SM — Marine LV Transformers in an IP23 Enclosure (400–1 600 kVA). We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What power do the ET3SM marine transformers have?

The range is from ET3SM-400 to ET3SM-1600, that is from 400 to 1 600 kVA. Intermediate models are 500, 630, 800, 1000 and 1250 kVA.

What are the degree of protection and the enclosure colour?

Steel enclosure IP23, powder paint RAL 7035. The colour can be changed at the request of the project.

How are cables connected to ET3SM?

Supply cables are brought in through the floor of the enclosure. Terminals are made as clamps of 10–240 mm² or copper busbars.

Which register approvals are available?

Depending on the order, made to the rules of GL, PRS, RMRS, RINA, LR, BV, DNV, ABS and NATO, as well as to EN/IEC 60726 and EN/IEC 61558.

Similar products

Power transformers

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.