ET1MED / ET3MED — Medical Isolating Transformers 2.5–10 kVA for IT Networks of Group 2 Rooms (Operating Theatres, Intensive Care), EN 61558-2-15

Isolating transformers with a power from 2.5 to 10 kVA for medical IT networks in group 2 rooms, such as operating theatres and intensive care. Single-phase ET1MED have a voltage of 230/230 V or 220/220 V, three-phase ET3MED 3×400/3×230 V. The leakage current does not exceed 0.2 mA, made to PN-EN 61558-2-15:2011.

Types
ET1MED — single-phase; ET3MED — three-phase
Power
2.5; 3.15; 4.0; 5.0; 6.3; 8.0; 10.0 kVA
ET1MED voltages
230/230 V or 220/220 V, 50 or 60 Hz; middle tap 2M for the insulation monitoring relay
ET3MED voltages
3×400 V / 3×230 V, vector group YNyn0, 50 Hz

Technical specifications

TypesET1MED — single-phase; ET3MED — three-phase
Power2.5; 3.15; 4.0; 5.0; 6.3; 8.0; 10.0 kVA
ET1MED voltages230/230 V or 220/220 V, 50 or 60 Hz; middle tap 2M for the insulation monitoring relay
ET3MED voltages3×400 V / 3×230 V, vector group YNyn0, 50 Hz
Short-circuit voltage< 3 % Un
No-load current< 3 % In
Leakage currentnot more than 0.2 mA
Inrush currentnot more than 12 In
Insulationdouble, screen between windings (terminal S); thermal class B (130 °C); protection class I
Temperature monitoringPTC-120 thermistors
VersionC1/E0 (land), ambient 40 °C; IP00, to order IP23/IP44/IP54
WeightET1MED 29–80 kg; ET3MED 42–106 kg
StandardPN-EN 61558-2-15:2011

Replacement for

isolating OSM1, TSZI; no specialised medical (IT network) analogue

selected by purpose and main parameters, please confirm with the manager

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

In group 2 rooms current can flow through the patient's body, so the supply is provided through a transformer without an earthed neutral on the consumer side. The first earth fault then does not switch off the equipment but is only signalled. The windings have double insulation, with an electrostatic screen between them connected to an insulated terminal S. The short-circuit voltage and the no-load current are below 3 %, and the inrush current does not exceed 12 In. Thermal class B (130 °C), protection class I, and PTC-120 thermistors are built into each winding for temperature monitoring. ET1MED has a middle tap 2M for the insulation monitoring relay, and ET3MED has the vector group YNyn0 and a frequency of 50 Hz. The standard version is open, IP00, C1/E0, ambient temperature 40 °C, with vertical mounting on angle brackets. The weight of single-phase units is from 29 to 80 kg, of three-phase units from 42 to 106 kg.

How to choose

The type is determined by the network: ET1MED for single-phase supply, ET3MED for three-phase. The power is chosen from the series 2.5, 3.15, 4.0, 5.0, 6.3, 8.0 and 10.0 kVA according to the total load of the operating theatre or ward. For installation in general rooms, an IP23, IP44 or IP54 enclosure is ordered. The manufacturer also supplies the medical IT network automation with insulation monitoring and redundancy as a set. Other powers and parameters are made to order.

Request a price and lead time

ET1MED / ET3MED — Medical Isolating Transformers 2.5–10 kVA for IT Networks of Group 2 Rooms (Operating Theatres, Intensive Care), EN 61558-2-15. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Why is an isolating transformer needed in an operating theatre?

It creates an isolated IT network in which the first earth fault does not switch off the equipment but is only signalled. This is critical for group 2 rooms.

What power and voltage do ET1MED and ET3MED have?

Power from 2.5 to 10.0 kVA from a series of seven values. ET1MED at 230/230 V or 220/220 V at a frequency of 50 or 60 Hz, ET3MED at 3×400 V / 3×230 V.

What leakage current do these transformers have?

Not more than 0.2 mA. A screen with terminal S is placed between the primary and secondary windings.

What is the middle tap 2M for?

The insulation monitoring relay in single-phase ET1MED is connected to it.

Is there overheating protection?

Yes, PTC-120 thermistors are built into each winding. The thermal class of the insulation is B (130 °C).

Similar products

Power transformers

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.