Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

POWER TRANSFORMERS

TU_ / TUC_ / TL_ / TU_PS plastic-housing measuring current transformers, 50–6000 A (including slim profile)

The TU_, TUC_, TL_ and TU_PS series measuring current transformers in a plastic housing cover primary currents from 50 to 6000 A. The windows suit busbars from 20×5 to 125×50 mm and cable from Ø16 to Ø70 mm. They are mounted in distribution boards and main switchboards for ammeters, network analyzers and energy meters.

Primary current
50–6000 A (TL_ — 750–6000 A for high currents)
Accuracy class
0.5; 1; 3 (0.2S; 0.2; 0.5S on request)
TU_ windows
busbars 20×5, 30×10, 40×10 mm; cable Ø16–Ø30
TUC_ windows
busbars 30×10–80×30 mm; cable Ø25–Ø65

Technical specifications

Primary current50–6000 A (TL_ — 750–6000 A for high currents)
Accuracy class0.5; 1; 3 (0.2S; 0.2; 0.5S on request)
TU_ windowsbusbars 20×5, 30×10, 40×10 mm; cable Ø16–Ø30
TUC_ windowsbusbars 30×10–80×30 mm; cable Ø25–Ø65
TL_ windowsbusbars 100×20, 100×30, 100×60 mm
TU_PS (slim profile)TU20PS…TU125PS: busbars 20×6–125×50 mm, 60–4000 A
TU_PS-3three phases in one housing
TU100PSHdual secondary winding, busbar 100×30/80×50, 400–1500 A and above
Max. operating voltage720 V
Test voltage3 kV AC, 1 min
Secondary currentx/5 A, x/1 A
Frequency50–60 Hz
StandardsIEC 61869-1/-2, IEC 60185, IEC 61010

Replacement for

T-0.66, TShP-0.66, TOP-0.66, TShL-0.66, TNSh-0.66 (current transformers 0.66 kV, 5–5000 A)

selected by purpose and main parameters, please confirm with the manager

Replacement pages: ТНШ-0,66, ТНШ, ТОП-0,66, ТОП, ТШП-0,66, ТШП

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The TU_ series covers compact feed-through models with 20×5, 30×10 and 40×10 mm busbars, Ø16, Ø22 and Ø30 mm cable and currents of roughly 50–1000 A. TUC_ units have windows for 30×10, 40×10, 50×10, 60×10 and 80×30 mm busbars, Ø25–Ø65 mm cable and currents up to 3000 A, and the 0.5S, 0.2 and 0.2S versions give higher accuracy; TUC40-1 has a 40 mm window. TL_ is chosen for 750–6000 A with 100×20, 100×30 and 100×60 mm busbars. The slim-profile TU20PS, TU30PS, TU40PS, TU50PS, TU60PS, TU80PS, TU100PS and TU125PS are designed for 20×6–125×50 mm busbars, Ø18–Ø70 mm cable and 60–4000 A. TU_PS-3 combines three phases in one housing, and TU20PS-1 is a miniature model for 30–400 A. TU100PSH, for a 100×30 or 80×50 mm busbar (cable Ø85), has two independent secondary windings with sealable terminal blocks.

How to choose

First determine the primary current and the way the conductor is run. For cable up to Ø30 mm and about 1000 A, TU_ is enough; for busbars up to 80×30 mm and 3000 A, TUC_ is suitable; and up to 6000 A, TL_ is used in 0.4 kV boards and busways. In a tight cabinet look at TU_PS, and for three phases in one housing, at TU_PS-3. Classes 0.5, 1 and 3 are standard, while 0.2S, 0.2 and 0.5S are ordered separately. If the cable cannot be disconnected, look at the split-core TA_P for 20–5000 A.

Request a price and lead time

TU_ / TUC_ / TL_ / TU_PS plastic-housing measuring current transformers, 50–6000 A (including slim profile). We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the highest current of TL_ and TU_PS?

TL_ are rated for 750–6000 A with 100×20, 100×30 and 100×60 mm busbars, and the slim TU_PS cover 60–4000 A.

What are the voltage, frequency and secondary current?

The maximum operating voltage is 720 V, the test voltage is 3 kV AC for 1 min, the frequency is 50–60 Hz, and the secondary current is x/5 A or x/1 A.

What are the overload and insulation margins?

Continuous overload is 1.2 In, the thermal withstand current is 60 In, the dynamic current is 2.5 Ith, and Fs < 5. Insulation class E, class B (130 °C) on request.

Which standards do these transformers comply with?

IEC 60185, IEC 61010, IEC 61869-1/-2, UNE-EN 61000-6-1 and 61000-6-3, UL94-V0, VDE 0414, DIN 57414 and BS 3938. CE declarations are available for TU_, TUC_, TL_, TU_PS and TU20PS-1.

Similar products

Power transformers

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.