POWER TRANSFORMERS

TPR_ / TPR_B / TU_CP / TU_R / TUC_ / TL_ / TUP_R protection current transformers 5P/10P, including zero-sequence CTs

The TPR_, TPR_B, TU_CP, TU_R, TUC_, TL_ and TUP_R protection current transformers have classes 5P10, 5P20, 10P10 and 10P20 and work in the 50–5000 A range. They supply relay protection, breaker trip units and monitoring relays in 0.4 kV installations, and the zero-sequence TUP_R monitor earth faults.

Protection class
5P10, 5P20, 10P10, 10P20
Primary current
50–5000 A (depending on model)
TPR_
TPR60, TPR80, TPR100, TPR125: cable Ø60–Ø125 mm; 100–5000 A; up to 120 VA
TPR_B
TPR80B, TPR100B, TPR125B: busbars 50×50, 105×45, 122×52 mm; 250–5000 A

Technical specifications

Protection class5P10, 5P20, 10P10, 10P20
Primary current50–5000 A (depending on model)
TPR_TPR60, TPR80, TPR100, TPR125: cable Ø60–Ø125 mm; 100–5000 A; up to 120 VA
TPR_BTPR80B, TPR100B, TPR125B: busbars 50×50, 105×45, 122×52 mm; 250–5000 A
TU_CP / TU_Rwound primary, 50–800 A
TUC_ / TL_plastic feed-through, 200–2500 / 2000–5000 A
TUP_R zero-sequenceTUP310R, TUP300R, TUP900R: windows 310×80, 384×84, 905×145 mm; 60/1 A; 5P10; 0.25 VA
Max. operating voltage720 V
Test voltage3 kV AC, 1 min
Secondary currentx/5 A, x/1 A
Frequency50–60 Hz
StandardsIEC 61869-1/-2, IEC 60185, IEC 61010

Replacement for

T-0.66, TShP-0.66, TOP-0.66, TShL-0.66, TNSh-0.66 (current transformers 0.66 kV, 5–5000 A); TZLM, TZRL, TZLK (zero-sequence)

selected by purpose and main parameters, please confirm with the manager

Replacement pages: ТНШ-0,66, ТНШ, ТОП-0,66, ТОП, ТШП-0,66, ТШП

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Protection transformers keep the specified error at short-circuit currents many times higher than the rated current, so they are used to supply protection relays and trip units. TPR60, TPR80, TPR100 and TPR125 are filled with resin, have Ø60, Ø80, Ø100 and Ø125 mm windows and currents of 100–5000 A, and the burden reaches 120 VA in class 5P10 (TPR60 at 5000 A) and 70 VA in class 5P20. TPR_B is chosen for 50×50, 105×45 and 122×52 mm busbars (cable Ø45–Ø52) at 250–5000 A. TU_CP and TU_R with a wound primary cover 50–800 A, TUC_ and TL_ give 200–2500 and 2000–5000 A, and TUP_R work at 500–5000 A. The zero-sequence transformers TUP310R, TUP300R and TUP900R have windows of 310×80, 384×84 and 905×145 mm, a rating of 60/1 A, class 5P10, a burden of 0.25 VA, an overload of 1.5 In and a 2×2.5 mm² secondary cable.

How to choose

Choose by protection class and type of primary circuit. For cable take TPR_ with Ø60–Ø125 mm windows, for a busbar TPR_B, and for small currents up to 800 A, TU_CP or TU_R will do. For measuring earth-fault current you need TUP310R, TUP300R or TUP900R, with all phases passing through the window. If only metering is needed, look at the measuring TU_R for 25–6000 A.

Request a price and lead time

TPR_ / TPR_B / TU_CP / TU_R / TUC_ / TL_ / TUP_R protection current transformers 5P/10P, including zero-sequence CTs. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How does a protection transformer differ from a measuring one?

It keeps the specified error at short-circuit currents many times higher than the rated current. The protection classes are 5P10, 5P20, 10P10 and 10P20, and TP and TPx models are made to order.

How is earth-fault current measured?

All phase conductors are passed through the large window of TUP310R, TUP300R or TUP900R. The rating is 60/1 A, class 5P10, burden 0.25 VA.

What are the general parameters and operating temperature?

720 V, 3 kV AC for 1 min, 50–60 Hz, thermal withstand 60 In, dynamic current 2.5 Ith, overload 1.2 In, temperature −5…+40 °C. Secondary current x/5 A or x/1 A, insulation class E (B on request).

Which standards and CE declarations apply to the series?

IEC 60185, IEC 61010, IEC 61869-1/-2, UNE-EN 61000-6-1 and 61000-6-3, UL94-V0, VDE 0414, DIN 57414 and BS 3938. CE declarations are available for TPR60–TPR125, TUP85R–TUP900R, TU3BCP, TU40CP and TU3R.

Similar products

Power transformers

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.