Summation current transformers LU01

LU01 are summation current transformers that add the secondary currents of several main current transformers. The total can then be read with a single meter. The output current stays a standard quantity.

Technical specifications

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

A summation transformer takes the secondary currents of several measuring current transformers working in the same phase and delivers a single current at its output. The typical case is several lines or feeders whose combined current has to be shown, recorded or sent to a meter. Without LU01 you would need a separate instrument on every line or have to add readings by hand. The output current is again a standard quantity, because the primary currents are added and then divided by the number of inputs, so the instrument scale stays familiar. The module is built in a plastic housing with terminals at the top and bottom and is mounted in a panel next to the measuring instruments. It matters that the summed currents are synchronous and share the same phase relation.

How to choose

The main criterion is the number of lines whose currents have to be added, since that is the number of inputs required. Also check that all main current transformers work in the same phase, because a sum of out-of-phase currents gives a wrong result. For a single feeder a summation transformer is unnecessary and an ordinary current transformer is enough. Before ordering, confirm the rated secondary current of the main transformers so that the summation inputs match them.

Request a price and lead time

Summation current transformers LU01. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What does the LU01 summation current transformer do?

It adds the secondary currents of several main current transformers so that they can be measured with one meter.

Does the output current remain standard?

Yes. The primary currents are added and also divided by the number of inputs, so the output is a standard quantity.

Which currents can be summed?

Synchronous alternating currents with the same phase relation.

Why sum currents at all?

To measure the total load of several lines with one measuring instrument instead of several.

Can currents of different phases be summed?

No. Only synchronous currents with the same phase relation are summed, otherwise the result is wrong.

Similar products

Power transformers

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.