Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

TEST AND MEASUREMENT

Smart Meter — bidirectional energy meters for PV energy systems

The Smart Meter bidirectional meter comes in single-phase and three-phase models from 63A-1 to 5kA-3 and is installed at the grid connection point. It records consumption, grid import and grid export, and energy management in systems with a battery, Wattpilot charger and Ohmpilot controller runs on this data.

Series
Smart Meter, Smart Meter TS, Smart Meter IP, Smart Meter WR
Models
63A-1, 63A-3, 65A-3, 100A-1, 5kA-3 (single-phase, three-phase, high-current with current transformers)
Measurement
bidirectional: consumption, grid import and grid export
Interfaces
RS 485 (Modbus RTU), Modbus TCP/IP, LAN/Wi-Fi depending on model

Technical specifications

SeriesSmart Meter, Smart Meter TS, Smart Meter IP, Smart Meter WR
Models63A-1, 63A-3, 65A-3, 100A-1, 5kA-3 (single-phase, three-phase, high-current with current transformers)
Measurementbidirectional: consumption, grid import and grid export
InterfacesRS 485 (Modbus RTU), Modbus TCP/IP, LAN/Wi-Fi depending on model
Ingress protectionIP20–IP51 depending on series
MountingDIN rail, spring terminals (IP series)
More from the manufacturer’s documentation
Nominal voltage230–400 V (63A-3); 230–240 V (63A-1); 230 V (TS 100A-1); 208–400 V (TS 65A-3); 100–240 V / 3 × 208–480 V (IP 5kA-3); 120–600 V (WR 100-600 V-3)
Operating voltage tolerance±15 % (63A-3, WR); ±10 % (63A-1, IP 5kA-3); −30 to +20 % (TS 100A-1); ±20 % (TS 65A-3)
Max. current3 × 63 A (63A-3); 1 × 63 A (63A-1); 1 × 100 A (TS 100A-1); 3 × 65 A (TS 65A-3); 3 × 5,000 A (IP 5kA-3, via CTs); 3 × 6,000 A (WR, via CTs)
Grid frequency50–60 Hz (63A, IP); 45–65 Hz (TS, WR)
Grid types3PN (63A-3); 1PN (63A-1, TS 100A-1); 2PN, 3P, 3PN (TS 65A-3); 1PN, 2PN, 3PN (IP); 1PN, 2P, 2PN, 3P, 3PN (WR)
Accuracy classactive energy: class B (EN 50470-3) / class 1 (EN 62053-21); reactive: class 2 (EN 62053-23); WR: ANSI C12.20 class 0.5
Power consumption1.5 W (63A); ≤ 1 W (TS); 5 W (IP 5kA-3); 1.75 W (WR)
Short-time overcurrent30 × Imax / 0.5 s (63A); 3,000 A / 10 ms (TS 100A-1); 1,950 A / 10 ms (TS 65A-3); 3 × Imax / 20 s (IP 5kA-3)
Power line cross-section1–16 mm² (63A, TS 65A-3); 1–25 mm² (TS 100A-1); 1.5–4 mm² (IP 5kA-3); up to 2.5 mm² (WR)
Housing4 DIN 43880 modules (63A-3); 2 modules (63A-1, TS 100A-1); 3 modules (TS 65A-3, IP 5kA-3); WR wall-mounted
Dimensions (H × W × D)89.0 × 71.2 × 65.6 mm (63A-3); 89.0 × 35.0 × 65.6 mm (63A-1); 91.5 × 35.8 × 63.0 mm (TS 100A-1); 91.5 × 53.8 × 63.0 mm (TS 65A-3); 90 × 53 × 58 mm (IP 5kA-3); 153 × 85.1 × 38.0 mm (WR)
Weight260 g (63A-3); 250 g (63A-1); 160 g (TS 100A-1); 240 g (TS 65A-3); 132 g (IP 5kA-3); 233 g (WR)
Operating temperature−25 to +55 °C (63A, IP); −25 to +65 °C (TS); −40 to +80 °C (WR)
Display8-digit LCD (63A-3); 6-digit LCD (63A-1); 3 × 8-digit touchscreen (TS)
Current transformersIP 5kA-3: primary 1–5,000 A, WR: 1–6,000 A, secondary 333 mV voltage output; Smart Meter CT 100 / 250 / 400 A, split-core, diameter 16 / 24 / 36 mm, 1 m cable, −40 to +65 °C
Export limitationset as 0–100 % or in watts (via Datamanager)
Compatibilityall GEN24 Plus, inverters with Datamanager 2.0, Ohmpilot
Conformity (TS 100A-1)directives 2014/30/EU, 2014/35/EU, 2011/65/EU; EN 61010-1, EN IEC 61010-2-030, EN 61326-1, EN IEC 63000
Customs codes (for reference)
HS code9028.30
UKTZED code (Ukraine)9028301900 (multiphase)
CN code (EU)90283019 (multiphase)

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The line includes the Smart Meter, Smart Meter TS, Smart Meter IP and Smart Meter WR series. Models 63A-1, 63A-3, 65A-3, 100A-1 and 5kA-3 cover single-phase and three-phase connections, and the largest one handles high currents through current transformers. Direct connection goes up to 3 × 63 A on the 63A-3 and 1 × 100 A on the TS 100A-1, while the IP 5kA-3 measures up to 3 × 5,000 A through CTs with a 333 mV output. Active energy is metered to class B (EN 50470-3) and reactive energy to class 2. Depending on the model, communication runs over RS 485 (Modbus RTU), Modbus TCP/IP or LAN/Wi-Fi. Ingress protection ranges from IP20 to IP51 by series. The meters mount on a DIN rail, the IP series uses spring terminals, and the three-phase 63A-3 takes 4 DIN 43880 modules.

How to choose

Choose the model by service current and by the link to the inverter. A single-phase house takes the 63A-1, a three-phase service up to 63 A per phase the 63A-3, and anything larger the 5kA-3 with split-core Smart Meter CT transformers of 100, 250 or 400 A. If no twisted pair for RS 485 can be run from the panel to the inverter, take the IP series with LAN or Wi-Fi. Export limitation is then set through Datamanager as 0–100 % or in watts.

Request a price and lead time

Smart Meter — bidirectional energy meters for PV energy systems. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What interfaces does Smart Meter have?

RS 485 (Modbus RTU), Modbus TCP/IP or LAN/Wi-Fi, depending on the model.

Which Smart Meter is used for high currents?

The 5kA-3 model, which works with current transformers and measures up to 3 × 5,000 A.

What ingress protection do Smart Meter units have?

From IP20 to IP51 depending on the series, with DIN rail mounting.

Can Smart Meter be used to limit grid export?

Yes, an export limit of 0–100 % or in watts is set in Datamanager, and the meter at the connection point supplies the actual power for it.

Similar products

Test and measurement

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.