Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

TEST AND MEASUREMENT

Energy Meter (KEM) three-phase energy meter for PLENTICORE

The KEM three-phase energy meter tracks household consumption and grid exchange around the clock in systems with PLENTICORE hybrid inverters, at up to 100 A direct connection. A separate Energy Meter MP version serves the single-phase PLENTICORE MP.

Compatibility
PLENTICORE plus G2, PLENTICORE G3, Multi Device Control, ENECTOR G2
MP version
single-phase (L1), DIN rail, Modbus RTU / RS485, for PLENTICORE MP

Technical specifications

CompatibilityPLENTICORE plus G2, PLENTICORE G3, Multi Device Control, ENECTOR G2
MP versionsingle-phase (L1), DIN rail, Modbus RTU / RS485, for PLENTICORE MP
More from the manufacturer’s documentation
VersionsSeries C and Series P (three-phase), MP Series P (single-phase)
Rated voltagemax. 208/415 V~ (C) / 3 × 230/400 V (P) / 230 V (MP-P)
Frequency50/60 Hz (C, MP-P) / 50 Hz (P)
Max. current (direct connection)65 A (C) / 100 A (P, MP-P)
Base / reference current5 A (C) / 10 A (P, MP-P)
Accuracy classactive energy class 1 (EN 62053-21), reactive energy class 2 (EN 62053-23)
Meter typebidirectional (P, MP-P)
InterfaceRS485, Modbus RTU; 38,400 bps (P)
Meter constant400 imp/kWh (P) / 1,000 imp/kWh (MP-P)
Power consumption< 1.3 W / 2.6 VA (C) / 2 W, 10 VA (P, MP-P)
MountingDIN rail (C: 3 modules; P, MP-P: DIN 43880)
Dimensions (H × W × D)90 × 53.4 × 62.4 mm (C) / 100 × 72 × 66 mm (P) / 90 × 18 × 66 mm (MP-P)
Weight270 g (C) / 322 g (P) / 90 g (MP-P)
Protection ratingIP40 front / IP20 terminals (C); IP20 (P, MP-P)
Operating temperature−25…+55 °C (C) / −40…+70 °C (P, MP-P)
Relative humidityup to 90 % (C, P) / 95 % (MP-P), non-condensing
Max. installation altitude2,000 m
Measuring conductor cross-section2.5–16 mm² (C) / 4–25 mm² (P) / 1.5–6 mm² (MP-P)
Impulse withstand6 kV (1.2/50 µs), 4 kV for 1 minute (P, MP-P)
StandardsEN 62052-11, EN 61010-1, EN IEC 63000 (C)
Warranty2 years
Customs codes (for reference)
HS code9028.30
UKTZED code (Ukraine)9028301900 (multiphase)
CN code (EU)90283019 (multiphase)

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The meter works with PLENTICORE plus G2 and PLENTICORE G3 inverters, the Multi Device Control and the ENECTOR G2 charger. The three-phase Series C and Series P connect directly at 65 A and 100 A respectively, and the single-phase MP Series P also carries 100 A. Series P and MP-P are bidirectional and count imported and exported energy separately, at accuracy class 1 for active and class 2 for reactive energy. The single-phase MP version measures phase L1 and mounts on a DIN rail in the board, in an 18 mm wide housing. It talks to the PLENTICORE MP over Modbus RTU on RS485, and Series P runs at 38,400 bps. Measuring conductors are 2.5–16 mm² for C, 4–25 mm² for P and 1.5–6 mm² for MP-P. IP20 terminals mean the meter belongs inside an enclosure.

How to choose

Choose the version by supply and current, with Series C enough for a three-phase service up to 65 A, Series P up to 100 A, and MP Series P for the single-phase 3–7 kW PLENTICORE MP. Sites with PIKO CI 30 / 50 / 60 grid-tied inverters, or those that need self-consumption control, get the KSEM, which works with every inverter of the brand.

Request a price and lead time

Energy Meter (KEM) three-phase energy meter for PLENTICORE. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Which devices work with the Energy Meter?

The PLENTICORE plus G2, PLENTICORE G3, Multi Device Control and ENECTOR G2.

What interface does the Energy Meter MP use?

Modbus RTU over RS485, with DIN rail mounting and an 18 mm wide housing.

Which meter does the PLENTICORE MP need?

The single-phase Energy Meter MP, which measures phase L1 and connects directly up to 100 A.

Does the KEM need current transformers?

No, it connects directly up to 65 A on Series C and 100 A on Series P.

What accuracy class does the KEM have?

Class 1 for active energy under EN 62053-21 and class 2 for reactive energy under EN 62053-23.

Similar products

Test and measurement

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.