REVO S, CD3000S, REVO SSR, REVO SX — solid-state relays with heatsink, 1/2/3 phases, 3.5–800 A, up to 690 V

Solid-state relays with heatsink come in single-, two- and three-phase versions for 3.5 to 800 A at up to 690 V. They switch heaters on command from a temperature controller or PLC in furnaces, extruders, moulding and packaging machines and IR heating.

REVO S 1PH/2PH/3PH
3.5–800 A; 480, 600, 690 V (690 V from 60 A) ±10 %
CD3000S 1PH/2PH/3PH
10–90 A (3PH 15–90 A); 24–480 V, 600 V on request
REVO SSR
long-life relay; version with 0–10 V / 4–20 mA analog input
REVO SX
multichannel relays: 2×7 A, 3×4.5 A, 4×3.5 A; 50–90 A

Technical specifications

REVO S 1PH/2PH/3PH3.5–800 A; 480, 600, 690 V (690 V from 60 A) ±10 %
CD3000S 1PH/2PH/3PH10–90 A (3PH 15–90 A); 24–480 V, 600 V on request
REVO SSRlong-life relay; version with 0–10 V / 4–20 mA analog input
REVO SXmultichannel relays: 2×7 A, 3×4.5 A, 4×3.5 A; 50–90 A
Firing modeszero crossing (ZC), burst 4/8/16 cycles
Loadresistive, long- and medium-wave IR lamps
Input4–30 V DC logic (SSR); 4–20 mA / 0–10 V optional
Load monitoringheater break (HB) with auto setup, relay and LED; CD3000S adds thyristor short-circuit diagnostics
Designhigh-dissipation heatsink, side-by-side mounting, IP20; DIN rail up to 90 A
ApprovalsCE, EMC, cULus 508 up to 700 A (option), UL for 800 A

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Unlike a contactor, the thyristor switch closes at the voltage zero crossing, with no arc, interference or wear, so it copes with switching every few seconds for tight temperature control. The main REVO S series has single-, two- and three-phase versions for 3.5–800 A at 480, 600 or 690 V, 690 V from 60 A. Under analog control it fires in bursts of 4, 8 or 16 cycles. The standard input is a 4–30 V DC logic signal, with 4–20 mA or 0–10 V on request. Control and power circuits are fully isolated, and input current is constant whatever the supply voltage. Optional break monitoring trips an alarm relay and an LED on partial or total heater failure, with an automatically set threshold. The high-dissipation heatsink lets relays sit side by side, rated IP20. Approvals are CE, EMC, cULus 508 up to 700 A on request and UL for 800 A.

How to choose

The compact CD3000S for 10–90 A at 24–480 V (600 V on request) mounts on a DIN rail up to 90 A and on a panel from 110 A, with optional analog input and break monitoring with thyristor short-circuit diagnostics. REVO SSR is for longer service life, also with analog input. REVO SX offers 2–4 channels of 3.5–7 A or a 50–90 A version for small heaters. These relays give no phase angle voltage control like ROT regulators, so for that take REVO C or REVEX.

Request a price and lead time

REVO S, CD3000S, REVO SSR, REVO SX — solid-state relays with heatsink, 1/2/3 phases, 3.5–800 A, up to 690 V. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Why use a solid-state relay instead of a contactor for heaters?

It switches at voltage zero crossing without arcing or contact wear, so it handles the switching every few seconds that tight temperature control needs.

From what current is REVO S available for 690 V?

The 690 V version starts at 60 A, while for 480 and 600 V the range runs from 3.5 to 800 A.

How does REVO S signal a broken heater?

Optional HB heater break monitoring switches an alarm relay and an LED, with an automatic trip threshold.

Which relays mount on a DIN rail?

CD3000S mounts on a DIN rail up to 90 A, and versions above 110 A go on a panel.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.