Thyro-S — digital thyristor switch, 1/2/3 phases, 8–350 A, 230–500 V

Thyro-S is a digital thyristor switch for heating loads of 8–350 A on 230, 400 and 500 V networks, with no mechanical contacts. It replaces contactors where heaters switch often, in panels of electric furnaces, pipeline trace heating, extruders and IR dryers.

Phases
1S — 1 phase; 2S — 3-phase load in 2-phase circuit without neutral; 3S — 3 phases
Rated current
8–350 A
Rated voltage
230–500 V (−57 %…+10 % or −15 %…+10 % depending on version)
Frequency
47–63 Hz

Technical specifications

Phases1S — 1 phase; 2S — 3-phase load in 2-phase circuit without neutral; 3S — 3 phases
Rated current8–350 A
Rated voltage230–500 V (−57 %…+10 % or −15 %…+10 % depending on version)
Frequency47–63 Hz
Modeon/off (TAKT), triggered by an external on/off controller or PLC
Loadresistive and transformer
Setpoint inputslogic input 0–24 V DC (on > 3 V); system interface to fieldbus module
Load monitoringthreshold, relay (250 V, 6 A), analog output 0(2)–10 V / 0(4)–20 mA — H RLP3 version
Protectionbuilt-in semiconductor fuse
Communicationmicro-USB (Thyro-Tool Pro); BasicBusModule — PROFIBUS DPV1, PROFINET, EtherNet/IP, Modbus TCP, EtherCAT, CANopen (up to 8 units)
MountingDIN rail up to 60 A
CertificatesCE, UL 508 (8–350 A), CSA C22.2 No. 14

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The switch serves as the final element of on/off control, taking its command from an external temperature controller, PLC or host computer via a 0–24 V DC logic input or a fieldbus module. Loads may be resistive or transformer-fed, at 47–63 Hz. 1S connects between two phases or phase and neutral, 2S drives a three-phase load in the economical two-phase circuit without neutral, and 3S is fully three-phase. Version H RLP3 adds load monitoring with an adjustable threshold, a 250 V, 6 A alarm relay and an analog indication output, and LEDs show status and load percentage. A built-in semiconductor fuse protects the power section, and the control circuits are galvanically isolated. Setup runs over micro-USB in Thyro-Tool Pro, BasicBus puts up to 8 units on one bus, and the optional Thyro-Power Manager smooths peaks when many heaters switch on together.

How to choose

Pick the circuit (1S, 2S or 3S) first, then the rated current with a margin over the heater current. Mains tolerance depends on the version, −57 %…+10 % or −15 %…+10 %, so check it against the plant network. Since the switch only turns the load on and off, ROT phase-angle regulators (Soviet-era single-phase thyristor voltage regulators) are replaced with Thyro-A for 8–1500 A, Thyro-A+ for 16–650 A or Thyro-PX for 16–5000 A and up to 1000 V.

Request a price and lead time

Thyro-S — digital thyristor switch, 1/2/3 phases, 8–350 A, 230–500 V. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How is the Thyro-S thyristor switch better than a contactor?

With no mechanical contacts, frequent switching causes no wear, sparking or burning. The 8–350 A range covers most furnace and dryer heaters.

How do I control Thyro-S from a PLC?

Apply the signal to the 0–24 V DC logic input, which switches on above 3 V. The other route is BasicBus with PROFINET, PROFIBUS DPV1, EtherNet/IP, Modbus TCP, EtherCAT or CANopen.

Can Thyro-S drive a three-phase heater without a neutral?

Yes, version 2S controls a three-phase load in a two-phase circuit without a neutral wire. Full three-phase control comes with 3S.

What certifications does Thyro-S have?

CE, UL 508 for units of 8–350 A and CSA C22.2 No. 14. Units up to 60 A mount on a DIN rail.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.