Three-phase stepped thyristor voltage stabilizers Hertz V3.0, 16.5–53 kW (3×25 … 3×80 A)
Country: Ukraine · Model: V3.0 3×25 – 3×80 A
The Hertz V3.0 series comprises three-phase stepped voltage stabilizers with thyristor switches for workshops, production shops, warehouses and retail facilities with three-phase loads. Each phase is regulated independently by switching transformer taps within 20 ms; there are no moving parts, and efficiency is not less than 98 %. The series is available in two versions: 16 steps with 2.3 % accuracy and 36 steps with 1 % accuracy. The 36-step version is recommended for protecting high-precision loads, server rooms and medical premises. The models are rated for current from 3×25 to 3×80 A and power from 16.5 to 53 kW, with an input operating range of up to 100…280 V.
- Rated current and power
- 3×25 A — 16.5 kW; 3×32 A — 22 kW; 3×40 A — 27 kW; 3×50 A — 33 kW; 3×63 A — 41 kW; 3×80 A — 53 kW
- Number of steps
- 16 or 36
- Stabilization accuracy
- 2.3 % (16 steps); 1 % (36 steps)
- Dimensions, max.
- 725×480×310 mm (25–63 A); 810×520×325 mm (80 A)
Technical specifications
| Rated current and power | 3×25 A — 16.5 kW; 3×32 A — 22 kW; 3×40 A — 27 kW; 3×50 A — 33 kW; 3×63 A — 41 kW; 3×80 A — 53 kW |
|---|---|
| Number of steps | 16 or 36 |
| Stabilization accuracy | 2.3 % (16 steps); 1 % (36 steps) |
| Dimensions, max. | 725×480×310 mm (25–63 A); 810×520×325 mm (80 A) |
| Weight, max. | 75; 75; 77; 77; 86; 96 kg (in order from 25 to 80 A) |
| Conductor cross-section per phase | from 4–16 mm² (min.) to 30–40 mm² (max.) |
| Switch type | thyristor |
| Efficiency | not less than 98 % |
| Output voltage | 220 V per phase |
| Stabilization range within stated accuracy | 150–260 V |
| Cut-off thresholds | Umin 100 V, Umax 280 V |
| Response time | 20 ms |
| Mains frequency | 45–65 Hz |
| Lower cut-off threshold adjustment | 60–135 V |
| Output voltage adjustment | 200–230 V |
| Cooling | forced, 2 two-speed fans |
| Degree of protection | IP20 |
| Climatic version | УХЛ, category 4.2 |
| No-load power | 20 W per phase |
Analogues in the catalogue
- ESR-3P-T1F — three-phase static voltage stabiliser 6–400 kVA
- ESR-3P-T2F/T3F — three-phase static voltage stabiliser 450–3125 kVA
- SVS-3P — three-phase servo-electronic voltage stabiliser 6–600 kVA
- AVR3x — three-phase static voltage stabilizer 18–190 kVA
- SVS3x35/45/75 — three-phase voltage stabilizers up to 54 kVA
- TS Series three-phase electromechanical voltage stabilizer 2.97-146 kVA
- SVR Series solid-state voltage stabilizer 5–400 kVA
- Infinity+ — thyristor voltage stabiliser up to 3200 kVA
- EMS (Commercial) — electromechanical stabiliser up to 4000 kVA
- Ministab / Sterostab Y — three-phase voltage stabilizers with per-phase regulation, 3–8000 kVA
- Ministab / Sterostab T — three-phase voltage stabilizers with common regulation, 3.5–800 kVA
- Lyra / Polaris / Taurus voltage stabilizers 1–100 kVA
- Three-phase static voltage stabilizer 30–60 kVA, 400 V ±2 %
- Three-phase servo-driven voltage stabilizer SRV33, 6–60 kVA, independent phase regulation
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
Main features: thyristor step switching, 20 ms; 16 or 36 steps, selectable; mechanical bypass (transit); phase synchronization function in incomplete-phase operation; two three-segment LED indicators per phase and a linear load bar; network analyzer with measurement of current and input power; protection against short circuit, overload and overheating; input and output chokes against RF interference, varistor surge protection; floor-standing installation, terminal connection.
Technical data: Rated current and power — 3×25 A — 16.5 kW; 3×32 A — 22 kW; 3×40 A — 27 kW; 3×50 A — 33 kW; 3×63 A — 41 kW; 3×80 A — 53 kW; Number of steps — 16 or 36; Stabilization accuracy — 2.3 % (16 steps); 1 % (36 steps); Dimensions, max. — 725×480×310 mm (25–63 A); 810×520×325 mm (80 A); Weight, max. — 75; 75; 77; 77; 86; 96 kg (in order from 25 to 80 A); Conductor cross-section per phase — from 4–16 mm² (min.) to 30–40 mm² (max.); Switch type — thyristor; Efficiency — not less than 98 %; Output voltage — 220 V per phase; Stabilization range within stated accuracy — 150–260 V; Cut-off thresholds — Umin 100 V, Umax 280 V; Response time — 20 ms; Mains frequency — 45–65 Hz; Lower cut-off threshold adjustment — 60–135 V; Output voltage adjustment — 200–230 V; Cooling — forced, 2 two-speed fans; Degree of protection — IP20; Climatic version — УХЛ, category 4.2; No-load power — 20 W per phase.
Application: workshops, production shops and warehouses with three-phase loads; machine tools, compressors, pumps, ventilation; server rooms and medical premises (36-step version); facilities with generators of proportionate power.
How to choose
We select the power rating, version and configuration to suit the load; delivery time and warranty terms are to be confirmed with the manager.
Similar products
Request a price and lead time
Three-phase stepped thyristor voltage stabilizers Hertz V3.0, 16.5–53 kW (3×25 … 3×80 A). We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.