ESR-3P-T2F/T3F — three-phase static voltage stabiliser 450–3125 kVA

The ESR-3P-T2F/T3F series covers powerful three-phase static stabilisers from 450 to 3125 kVA in 17 ratings for large sites and sensitive loads. Electronic regulation responds quickly to changes in a grid that may deviate by up to ±40 %.

Power
450–3125 kVA (17 ratings)
Grid
380–415 V, 190–240 V or 440–600 V
Input voltage range
up to ±40 %
Efficiency
≥ 95 %

Technical specifications

Power450–3125 kVA (17 ratings)
Grid380–415 V, 190–240 V or 440–600 V
Input voltage rangeup to ±40 %
Efficiency≥ 95 %
Regulationindependent per phase
Controldigital microprocessor, LCD display
Protectionsurge suppression, manual and automatic bypass

Ukrainian replacement/analogue

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Each phase is regulated independently, so the imbalance between phases, usual for factory grids with powerful single-phase consumers, is evened out at the output. A digital microprocessor control unit shows the parameters on an LCD display. Grids of 380–415 V, 190–240 V and 440–600 V are supported. Efficiency is at least 95 %, but at the level of thousands of kVA even a few percent of losses give noticeable heat that must be removed by ventilation. Built-in suppression protects the input against surges. A manual bypass takes the stabiliser out for maintenance without stopping the site, and the automatic one operates without an operator.

How to choose

The power is selected from the substation transformer or the main supply breaker, and among 17 ratings there is usually a close one. Below 450 kVA the ESR-3P-T1F for 6–400 kVA with a wider ±50 % input range is more appropriate. For single-phase lines there is the ESR for 3–100 kVA.

Request a price and lead time

ESR-3P-T2F/T3F — three-phase static voltage stabiliser 450–3125 kVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the power of the ESR-3P-T2F/T3F stabilisers?

From 450 to 3125 kVA, with 17 ratings in the series, so a suitable model can be found for most substation transformers.

Does the ESR-3P-T2F/T3F even out phase imbalance?

Yes, regulation is independent per phase, so each phase is brought to the nominal value separately.

What is the input voltage range of the T2F/T3F series?

Grid deviation of up to ±40 %. The smaller ESR-3P-T1F series has a wider range, up to ±50 %.

How is the stabiliser maintained without disconnecting the load?

Through the manual bypass the load is transferred directly to the grid and the stabiliser is taken out for repair. The automatic bypass operates by itself in case of a fault.

How is the operation of the ESR-3P-T2F/T3F monitored?

Control is digital and microprocessor-based, and the duty staff see the phase voltages and the unit status on the LCD display.

Similar products

Voltage stabilizers

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.