FAFW active harmonic filters

FAFW active harmonic filters work in 380–480 V networks at 47–63 Hz and compensate a current of 30–100 A. They suppress harmonics up to the 50th (51st) inclusive and compensate reactive power and load unbalance. They are installed in supply panels of frequency drives, UPS units, rectifiers and IT loads.

Voltage
380–480 V, 47–63 Hz
Compensation current
30–100 A (modular FAFW34030 with expansion)
Harmonics
up to the 50th (51st) harmonic, THDi < 5%
Response time
< 300 µs

Technical specifications

Voltage380–480 V, 47–63 Hz
Compensation current30–100 A (modular FAFW34030 with expansion)
Harmonicsup to the 50th (51st) harmonic, THDi < 5%
Response time< 300 µs
Protection degreeIP20
Parallel operationup to 5 filters
CommunicationEthernet, RS485, Modbus

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The filter measures the load current, extracts the harmonic components and injects into the mains a current of opposite phase, reducing THDi below 5%. The response time is below 300 µs, so the device keeps up with fast load changes of welding posts or drives. The modular version FAFW34030 allows expansion as the plant load grows. For larger currents up to 5 filters are connected in parallel. The IP20 protection degree means installation in a cabinet or in a closed electrical room. For integration into a metering and energy management system there are Ethernet, RS485 and the Modbus protocol. Unlike a passive LC filter, an active one is not tuned to a single frequency and does not resonate with capacitor banks.

How to choose

The rating is selected from the harmonic current to be compensated, not from the full load current. It is determined by measurements with a power quality analyzer at the connection point. If the measured harmonic current fits within 30–100 A, one filter is enough; otherwise several are installed in parallel, up to 5 units. For networks where the problem is reactive power without significant harmonics, a capacitor bank will be cheaper.

Request a price and lead time

FAFW active harmonic filters. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the compensation current of the FAFW active filter?

From 30 to 100 A depending on the model, and the modular FAFW34030 can be expanded.

Up to what order does FAFW suppress harmonics?

Up to the 50th (51st) harmonic inclusive, with THDi reduced below 5%.

How fast is the FAFW filter?

The response time is below 300 µs, so the filter handles abrupt load changes without noticeable delay.

How many FAFW filters can be connected in parallel?

Up to 5 filters, which makes it possible to compensate harmonic currents larger than the rating of a single device.

For what mains voltage is FAFW suitable?

For three-phase networks of 380–480 V at 47–63 Hz, with connection via Ethernet, RS485 or Modbus to a monitoring system.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.