DC PowerCube — charger / power supply, 24 V 150 A and 48 V 80 A

A charger module and DC power supply rated 24 V 150 A or 48 V 80 A. It takes energy from shore power or from a variable-speed Genverter DC generator and charges the battery banks of vessels and off-grid systems. The same unit can also feed a DC bus directly.

Models
24 V / 150 A, 48 V / 80 A
Charging from Genverter diesel generator
up to 4.5 kW (24 V / 150 A)
Mains charging
up to 3.5 kW, input 90–264 V, 45–65 Hz
Auxiliary output
12 V / 20 A

Technical specifications

Models24 V / 150 A, 48 V / 80 A
Charging from Genverter diesel generatorup to 4.5 kW (24 V / 150 A)
Mains chargingup to 3.5 kW, input 90–264 V, 45–65 Hz
Auxiliary output12 V / 20 A
Algorithm3-stage, lead-acid and lithium batteries
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504405500
CN code (EU)85044060

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

From a Genverter generator the 24 V / 150 A version accepts up to 4.5 kW. From the grid the module draws up to 3.5 kW with a 90–264 V input at 45–65 Hz, so one model runs on both European and American shore pedestals. The wide input also copes with the sagging voltage of a weak marina supply. Charging follows a 3-stage algorithm with profiles for lead-acid and lithium batteries. A separate 12 V / 20 A output feeds an auxiliary 12 V network such as navigation or lighting without an extra converter. Paired with a Genverter, the generator runs at variable speed and the DC PowerCube brings its output to bank voltage.

How to choose

Choose the model by bank voltage, 24 V / 150 A or 48 V / 80 A, and by the energy source. If charging comes from shore only and 60 or 100 A at 24 V is enough, the Supreme Pro with three outputs and a 90–265 V input will do. For 12 V banks at 20–100 A there is the Supreme, while the Supreme Multi with four outputs covers 12, 24 and 48 V. Topping up a 12 V battery from a 24 V network is a job for the MCC at 5–20 A.

Request a price and lead time

DC PowerCube — charger / power supply, 24 V 150 A and 48 V 80 A. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How much power does the DC PowerCube accept from a Genverter generator?

The 24 V / 150 A version accepts up to 4.5 kW.

What grid input voltage does the DC PowerCube accept?

The input is 90–264 V at 45–65 Hz, with up to 3.5 kW of charging power from the grid.

Does the DC PowerCube have a 12 V output?

Yes, an auxiliary 12 V / 20 A output for a secondary network.

What battery types can the DC PowerCube charge?

Lead-acid and lithium, using a 3-stage algorithm. The profile is set to match the bank type.

Will the DC PowerCube run on a 60 Hz supply?

Yes, it accepts 45–65 Hz at 90–264 V.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.