TMHyREC — IGBT rectifier for hydrogen electrolyzers 0.65–6 MW, up to 12 kA

The TMHyREC IGBT rectifier feeds green hydrogen electrolyzers with DC from 1 to 12 kA at powers from 650 to 6000 kW. It is used with alkaline, PEM and solid oxide (SOEC) electrolyzers in Power-to-X plants and electrochemical production.

Types
Type 10, 11, 11+, 12, 12+, 22, 22+, 23+
DC power
650 kW – 6000 kW
DC current
1–12 kA
AC input
420/440/500 V or 690 V, 50/60 Hz ±2 %

Technical specifications

TypesType 10, 11, 11+, 12, 12+, 22, 22+, 23+
DC power650 kW – 6000 kW
DC current1–12 kA
AC input420/440/500 V or 690 V, 50/60 Hz ±2 %
DC output50–720 V or 50–1000 V
TopologyPWM converter (IGBT) + IGBT chopper
Power factor> 0.99
HarmonicsIEEE 519, THDi < 3 %
Current ripple< 5 % (rms)
Coolingpower section — water, the rest — air
Installationindoor; 5–40 °C; up to 1000 m

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Instead of a thyristor bridge, a "PWM converter + IGBT chopper" chain works here, performing AC/DC and DC/DC conversion. The power factor exceeds 0.99, current harmonics comply with IEEE 519 with THDi below 3 %, and DC ripple does not exceed 5 % of the rms value. The electrolyzer in current-stabilization mode is loaded less, and the project does without reactive power compensators and harmonic filters, which would have to be included in the budget with a thyristor rectifier. For large electrolyzer parks the modules are placed in stackable containers and power is increased vertically on a minimal footprint.

How to choose

The type is selected by the stack current and power. The range is: Type 10 at 650 kW and 1 kA, Type 11 at 1800 kW and 3.75 kA, Type 11+ at 3000 kW and 4 kA, Type 12 at 1800 kW and 7.5 kA, Type 12+ at 3000 kW and 8 kA, Type 22 at 3600 kW and 7.5 kA, Type 22+ at 6000 kW and 8 kA, Type 23+ at 6000 kW and 12 kA. Power and current are built up by the number of PWM converter and IGBT chopper blocks, so for a 7.5 kA stack take Type 12 or Type 22 depending on the required power. If the stack voltage is above 720 V, a "+" model delivering up to 1000 V DC is needed.

Request a price and lead time

TMHyREC — IGBT rectifier for hydrogen electrolyzers 0.65–6 MW, up to 12 kA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What input voltage does the TMHyREC require?

Type 10, 11, 12 and 22 are connected to 420, 440 or 500 V AC, the "+" models to 690 V AC, and the mains frequency tolerance of 50/60 Hz is ±2 %.

What DC output voltage does the TMHyREC give?

Basic models regulate the output within 50–720 V DC, the "+" models within 50–1000 V DC, which suits stacks with a higher working voltage.

What installation conditions does the TMHyREC need?

The rectifier is installed indoors only, at a temperature of 5–40 °C and at an altitude up to 1000 m. The power section is cooled by water and the other parts by air, so a cooling water circuit must be brought to the cabinets.

What else can be taken for a hydrogen project together with the rectifier?

The same manufacturer supplies power supply systems from 300 kV, compressor drives (in the low-voltage class this is, for example, the TMdrive-10e2 at 460, 575 or 690 V), Solar Ware Ninja solar inverters at 800–880 kW and energy management systems.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.