EA PU 10000 — industrial programmable power supplies 30/60 kW

PU 10000 one-way industrial supplies deliver 30 kW in a 4U housing or 60 kW in 6U at a voltage of up to 2000 V and a current of up to 1000 A. They are used in automated test systems, to power electrolyzers and in high-power rack installations.

Power
30 kW (4U), 60 kW (6U)
Voltage
0–60 V … 0–2000 V
Current
0–40 A … 0–1000 A (4U); 0–80 A … 0–480 A (6U)
Efficiency
up to 96 %

Technical specifications

Power30 kW (4U), 60 kW (6U)
Voltage0–60 V … 0–2000 V
Current0–40 A … 0–1000 A (4U); 0–80 A … 0–480 A (6U)
Efficiencyup to 96 %
Supply208–480 V 3-phase (4U); 380–480 V 3-phase (6U), active PFC 0,99
Version19″, no display, housing depth 668 mm, IP20; water cooling option
StandardsEN 61010-1, EN 55011, EN 61326-1

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The units have no display, are controlled from the bench and are mounted in a 19″ rack; the housing depth is 668 mm. The 4U model gives a current from 0–40 A to 0–1000 A, the 6U model from 0–80 A to 0–480 A, and the voltage in both lines is from 0–60 V to 0–2000 V. Active input correction holds the power factor at 0,99, so a group of units hardly loads the grid with reactive power. Efficiency reaches 96 %. The supply is 208–480 V 3-phase for the 4U and 380–480 V 3-phase for the 6U. The protection rating is IP20, and water cooling is optional. The devices comply with EN 61010-1, EN 55011 and EN 61326-1.

How to choose

For an electrolyzer the current at low voltage is decisive, so look at the 4U with a current of up to 1000 A. For high-voltage circuits the 6U at 60 kW is more convenient. When energy has to be returned from the object, the same platform is offered by the bidirectional PUB 10000 with an efficiency of up to 96 %. Ready cabinets up to 300 kW per rack are supplied as High Power DC Racks, and for a laboratory desk with a need of up to 1500 W PSI 9000 DT is suitable.

Request a price and lead time

EA PU 10000 — industrial programmable power supplies 30/60 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What power do PU 10000 supplies have?

30 kW in the 4U housing and 60 kW in the 6U housing, with a voltage of up to 2000 V.

Is PU 10000 suitable for powering an electrolyzer?

Yes, powering electrolyzers is named among the main uses, and the 4U model delivers a current of up to 1000 A.

What is the power factor of PU 10000?

Active input correction holds the power factor at 0,99.

How does PU 10000 differ from PUB 10000?

PU only delivers energy to the load, while PUB 10000 also works as a load with regeneration to the grid.

What is the depth of the PU 10000 housing?

668 mm in the 19″ version, with an IP20 protection rating.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.