Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

DC-DC CONVERTERS AND BATTERY CHARGERS

Skylla, Centaur, Phoenix — industrial and marine battery chargers

Skylla, Centaur and Phoenix chargers run from a 90–265 V AC supply and have up to 3 isolated outputs. They charge lead-acid and lithium batteries on vessels, in telecom and at industrial sites, and can also work as a DC power supply.

Series
Skylla-TG 24/48 V, Skylla-TG GMDSS, Skylla-i 24 V, Skylla-IP65 12 V/70 A and 24 V/35 A, Centaur, Phoenix Smart IP43
Input
90–265 V AC (DC on some models)
Outputs
up to 3 isolated
Algorithm
IUoUo / adaptive 6-stage

Technical specifications

SeriesSkylla-TG 24/48 V, Skylla-TG GMDSS, Skylla-i 24 V, Skylla-IP65 12 V/70 A and 24 V/35 A, Centaur, Phoenix Smart IP43
Input90–265 V AC (DC on some models)
Outputsup to 3 isolated
AlgorithmIUoUo / adaptive 6-stage
CommunicationCAN (NMEA2000) on Skylla-i/IP65, Bluetooth on Smart IP43
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504405500
CN code (EU)85044060

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The Skylla-TG series comes in 24 and 48 V versions, with a Skylla-TG GMDSS variant for shipboard radio systems. The Skylla-i is a 24 V unit, and the Skylla-IP65 is made as 12 V/70 A and 24 V/35 A for damp spaces and open decks. Some models also accept a DC input. The wide 90–265 V AC range copes with sagging rural lines, generators and foreign shore power. Charging follows an IUoUo curve or an adaptive 6-stage algorithm, which shortens absorption after a shallow discharge and extends it after a deep one. Isolated outputs charge a starter battery and a service bank from one unit without tying the two banks together. The Skylla-i and Skylla-IP65 connect to a CAN bus (NMEA2000), and the Phoenix Smart IP43 is set up over Bluetooth.

How to choose

Pick the series by battery voltage and current, then by environment. The Skylla-IP65 at 12 V/70 A or 24 V/35 A goes where moisture is present, while the Phoenix Smart IP43 suits a dry plant room and is configured from a phone. Shipboard radio installations take the Skylla-TG GMDSS, and 48 V telecom banks the Skylla-TG 48 V. For a smaller vehicle or boat charger, the Blue Smart line in IP22, IP65 and IP67 reaches up to 94% efficiency. When the source is the vehicle alternator rather than AC, an Orion DC-DC charger such as the Orion XS 12/12-50A does the job.

Request a price and lead time

Skylla, Centaur, Phoenix — industrial and marine battery chargers. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What input voltage do Skylla chargers accept?

A 90–265 V AC supply, and some models also take a DC input.

How many outputs do Skylla and Centaur chargers have?

Up to 3 isolated outputs, so several batteries charge without being connected to each other.

What current ratings does the Skylla-IP65 have?

The Skylla-IP65 comes as 12 V/70 A and 24 V/35 A.

Can a Skylla charger work as a DC power supply?

Yes, these chargers also run as a DC power supply, feeding loads from the 90–265 V AC network.

Which Skylla model is meant for GMDSS radio equipment?

The Skylla-TG GMDSS, a variant of the Skylla-TG series that comes in 24 and 48 V versions.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.