AUPUS modular operational DC systems deliver 24–220 V DC and are built from MHE rectifier modules of 2000 W each with N+1 redundancy. They are installed in substations, industry, railway signaling and telecommunications.

Output voltage
24, 48, 60, 110, 125, 220 V DC
MHE module
2000 W (1500 W for 24 V), input 85–300 V AC
Efficiency
up to 97%
Cooling
natural, fanless

Technical specifications

Output voltage24, 48, 60, 110, 125, 220 V DC
MHE module2000 W (1500 W for 24 V), input 85–300 V AC
Efficiencyup to 97%
Coolingnatural, fanless
ControllerVIDI2/VIDI+: Ethernet, Modbus, IEC 61850, SNMP, RS-232
EIM inverters1–24 kVA, 1 and 3 phases, N+1
StandardsEN 61439-1/-2, IEC 62368-1, EN 50124-1, EN 50121-4/-5

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The voltage range covers 24, 48, 60, 110, 125 and 220 V DC, and for 24 V the module has a power of 1500 W. The modules accept an input of 85–300 V AC, so they withstand deep mains sags. Efficiency reaches 97%, cooling is natural and fanless, which means the cabinet has no wear part and does not collect dust. The enclosure is chosen for the site, from 5U/12U racks to wall-mounted WRS and floor-standing cabinets. The VIDI2 or VIDI+ controller transmits data via Ethernet, Modbus, IEC 61850, SNMP and RS-232, which simplifies connection to the substation process control system. The system is supplemented with EIM inverters of 1–24 kVA, single-phase or three-phase, also with N+1 redundancy. Compliance with EN 50124-1 and EN 50121-4/-5 relates to railway use, while EN 61439-1/-2 and IEC 62368-1 cover panel assembly and safety.

How to choose

Start with the nominal battery voltage and the total load and charging current, after which the number of MHE modules is determined as the required power plus one spare. The 5U/12U racks suit telecom cabinets, WRS small sites, and floor-standing cabinets substations. If the substation uses the IEC 61850 protocol, the VIDI controller supports it. When a single powerful rectifier up to 1000 A without modularity is needed, consider RDC.

Request a price and lead time

AUPUS HE / MHE / EIM modular N+1 operational DC systems. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the power of the MHE module in the AUPUS system?

2000 W per module, and 1500 W for 24 V systems. The module input is 85–300 V AC.

Does AUPUS support the IEC 61850 protocol?

Yes, the VIDI2/VIDI+ controller has IEC 61850, as well as Ethernet, Modbus, SNMP and RS-232.

What output voltages does AUPUS have?

24, 48, 60, 110, 125 and 220 V DC, which covers typical batteries of substations, telecom and railway signaling.

Does AUPUS have an inverter for AC consumers?

Yes, the EIM inverter system of 1–24 kVA, single-phase or three-phase, with N+1 redundancy.

What is the efficiency of AUPUS modular rectifiers?

Up to 97% with natural cooling and no fans.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.