Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

DC-DC CONVERTERS AND BATTERY CHARGERS

AIPCS — MV AC / 800 V DC converter for data centers

The AIPCS converts medium-voltage AC into DC for an 800 V DC bus and has a power of up to 3820 kVA. The platform was developed for data centers where racks with AI loads are powered directly from DC.

Power
up to 3820 kVA
DC voltage
up to 1000 V (800 V DC bus)
Efficiency
98 % with MV transformer
Max. temperature
up to 50 °C

Technical specifications

Powerup to 3820 kVA
DC voltageup to 1000 V (800 V DC bus)
Efficiency98 % with MV transformer
Max. temperatureup to 50 °C

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The platform accepts MV AC and forms a DC bus with a voltage of up to 1000 V, and the working bus value is 800 V DC. The 98 % efficiency is stated together with the MV transformer, that is, for the whole path from the line to the bus. The converter smooths the peak loads typical of AI clusters and thereby removes sharp consumption surges from the supply grid. Grid-forming mode means that the converter sets the voltage and frequency itself instead of following the grid. The equipment is designed to operate at temperatures up to 50 °C, which matters for data center technical areas with high heat density.

How to choose

The main selection parameters are the power of the data center section and the voltage of the DC distribution bus. One unit covers up to 3820 kVA, and larger halls are split into several sections. For the pumps and fans of the cooling systems of the same data center this manufacturer offers XMV670 / XMV660 Outdoor drives for 2.3–13.8 kV or low-voltage SD drives.

Request a price and lead time

AIPCS — MV AC / 800 V DC converter for data centers, Power Electronics. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the power of the AIPCS converter?

Up to 3820 kVA per unit. For a larger data center load several units are installed on separate bus sections.

What is the DC bus voltage in the AIPCS?

The working bus is 800 V DC, and the maximum voltage on the DC side is up to 1000 V.

What is the AIPCS efficiency including the transformer?

The manufacturer gives 98 % together with the MV transformer, that is, the losses from the grid to the DC bus are about two percent.

Why does the AIPCS need the grid-forming function?

In grid-forming mode the converter forms the voltage itself, so a data center with an AI load depends less on the state of the external grid.

Up to what temperature does the AIPCS operate?

The permissible temperature is up to 50 °C, which is taken into account when placing it next to other heat-generating equipment.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.