Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

DC-DC CONVERTERS AND BATTERY CHARGERS

Answer Drives DC / ADDvantage-32 / Mentor MP thyristor DC converters 3.7 kW – 12 MW

Compact three-phase thyristor converters for DC drives from 3.7 kW to 12 MW, with a current of 25–4000 A DC. They operate in two-quadrant or four-quadrant mode with fully digital control. They are installed on rolling mills, paper machines, cranes and excavators.

Power
3.7 kW – 12 MW
Current
25–4000 A DC
Input voltage
240–950 V AC
Output voltage
230–1500 V DC

Technical specifications

Power3.7 kW – 12 MW
Current25–4000 A DC
Input voltage240–950 V AC
Output voltage230–1500 V DC
Modestwo- and four-quadrant
Controlfully digital, auto-tuning
FamilyAnswer Drives DC, ADDvantage-32 (including Plus, DCP, DMG for motor-generator set control, AFS field controller), Mentor MP

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The input voltage is 240–950 V AC and the output is 230–1500 V DC. The family consists of Answer Drives DC, ADDvantage-32 and Mentor MP. For the ADDvantage-32 there is a Plus version, DCP panel drives, DMG digital control of motor-generator sets, the AFS field controller, and AFM and ACM modules that replace the control on an existing power section. Depending on the model, the drive has auto-tuning, a check of the tachogenerator state and connection at power-up, configuration without special tools, and display and logging of the main variables and faults. Modernization extends equipment service life, shortens installation downtime and removes the drift of analog systems.

How to choose

The drive is selected by armature current and voltage, since the ranges of 25–4000 A DC and 230–1500 V DC cover both small and heavy machinery. If reversing and regenerative braking are needed, the four-quadrant version is chosen. To renew an old power section, the AFM and ACM modules are suitable, DMG for motor-generator sets, and AFS for the field excitation. AC motors are fed by frequency converters, for example the AD5000 at 18.5–500 kW per drive.

Request a price and lead time

Answer Drives DC / ADDvantage-32 / Mentor MP thyristor DC converters 3.7 kW – 12 MW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the current and voltage range of the thyristor DC converters?

The current is 25–4000 A DC, the input voltage 240–950 V AC, the output 230–1500 V DC, and the power from 3.7 kW to 12 MW.

In which modes do these converters operate?

In two-quadrant and four-quadrant modes, with fully digital control and auto-tuning.

What do the Plus, DCP, DMG and AFS versions mean?

Plus is an extended ADDvantage-32, DCP is drives in a panel version, DMG is digital control of motor-generator sets, and AFS is a field excitation controller.

In which industries are these converters used?

In metallurgy, the paper, cement and shipbuilding industries, and also for cranes, hoists, excavators, test stands and the modernization of thyristor drives.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.