DC-DC CONVERTERS AND BATTERY CHARGERS
Selectiva 4.0 — chargers for traction lead-acid batteries
Country: Austria · Model: Selectiva 4.0
Selectiva 4.0 chargers rated 1–30 kW charge traction lead-acid batteries in forklifts and AGVs used in intralogistics. The range spans battery voltages of 12–80 V and currents from 20 to 375 A, and the manufacturer states a service life of up to 20 years.
- Battery type
- lead-acid traction
- Charging process
- Ri, adapts to battery condition
- Application
- forklifts and AGVs in intralogistics
- Certification
- CE, UL
Technical specifications
| Battery type | lead-acid traction |
|---|---|
| Charging process | Ri, adapts to battery condition |
| Application | forklifts and AGVs in intralogistics |
| Certification | CE, UL |
| Service life | up to 20 years (according to the manufacturer) |
| Connectivity | Charge & Connect cloud software |
| More from the manufacturer’s documentation | |
| Power classes | 1, 2, 3, 8, 16, 18 and 30 kW |
| Battery voltage | 12 / 24 / 36/48 / 72/80 V |
| Charging current | 20 A (Selectiva 1020) to 375 A (Selectiva 4.0 8375 30 kW) |
| Mains voltage | 1 × 230 V AC (±15 %) for 1–3 kW; 3 × 400 V AC (−10 / +30 %) for 8–30 kW; 3 × 220 V AC for 16 kW 48 V |
| Mains fuse | 16 A (1–8 kW); 32 A (16 / 18 kW); 63 A (30 kW) |
| Overall efficiency (mains to battery) | up to 84 % (device efficiency 93 % × charging efficiency 90 %, Ri process) |
| Dimensions (W × H × D) | 247 × 162 × 88 mm (1 kW); 341 × 198 × 110 mm (2 kW); 417 × 198 × 110 mm (3 kW); 633 × 344 × 180 mm (8 kW); 647 × 392 × 247 mm (16 kW); 785 × 392 × 247 mm (18 kW); 780 × 1,090 × 369 mm (30 kW) |
| Weight incl. leads | 4 / 6 / 8 / 23 / 37 / 47 / 104 kg (1 / 2 / 3 / 8 / 16 / 18 / 30 kW) |
| Degree of protection | IP40 (1 kW); IP21 (2, 3 kW); IP20 (8–30 kW); IP23 option |
| Lead length | mains 2–3 m, charging 2.5–3 m |
| Supported batteries | Pb-WET (PzS, GiS), Pb-CSM-WET, Pb-GEL (PzV, GiV), lead crystal; PzS, PzQ/PsQ, CSM characteristics |
| Charging characteristics | Ri, IUI, I-Puls; deep discharge, refresh, equalising charge, opportunity and fast charging |
| Functions | automatic battery voltage detection; calendar; peak load limitation; cooled-battery indication (blue LED); USB |
| Options | Gateway Link / LAN / WLAN; Aquamatic; Air-Puls (ECS); Cold Logistics; Power Charging; temperature-controlled charging; remote control (30 m); relay board; external start/stop |
| Warranty | 5 years ( terms); extension +12 / +36 months |
| Customs codes (for reference) | |
| HS code | 8504.40 |
| UKTZED code (Ukraine) | 8504405500 |
| CN code (EU) | 85044060 |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
Charging follows the gentle Ri process, which adapts to battery condition and extends battery life, with total mains-to-battery efficiency of up to 84 %. Besides Ri, the unit carries IUI and I-Puls characteristics, equalising, opportunity and fast charging, and recovery from deep discharge. The charger detects battery voltage by itself, and a blue LED shows when the battery has cooled and is ready for work. The 1–3 kW models run on 1 × 230 V and the 8–30 kW models on 3 × 400 V, with a 16, 32 or 63 A mains fuse depending on power. The units are CE and UL certified. The chargers connect to the Charge & Connect cloud software via Gateway Link, LAN or WLAN. The series covers lead-acid traction batteries, and a separate SelectION series exists for lithium-ion.
How to choose
Size the charger from the voltage and capacity of the truck battery. Charging current grows with power, from 20 A on the Selectiva 1020 to 375 A on the 30 kW model 8375, and the 30 kW unit already weighs 104 kg and needs a supply fused at 63 A. Cold stores get the Cold Logistics option, and flooded batteries can use the Aquamatic and Air-Puls systems. The warranty is 5 years, extendable by 12 or 36 months.
Request a price and lead time
Selectiva 4.0 — chargers for traction lead-acid batteries. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
Which batteries is Selectiva 4.0 for?
Lead-acid traction batteries in forklifts and AGVs, including Pb-WET (PzS, GiS), Pb-GEL (PzV, GiV) and lead crystal types.
What is the Ri charging process in Selectiva 4.0?
A gentle algorithm that adapts charging to battery condition and extends battery life. With it, total mains-to-battery efficiency reaches 84 %.
What is the service life of Selectiva 4.0?
Up to 20 years, according to the manufacturer.
What supply does a Selectiva 4.0 of 8–30 kW need?
A three-phase 3 × 400 V grid with a −10 / +30 % tolerance, fused at 16 A for 8 kW, 32 A for 16 and 18 kW, and 63 A for 30 kW.