SGR — fiberglass house connection cabinets for gas, water and electricity
Country: Germany · Model: SGR
SGR fiberglass house connection cabinets house the gas, water and electricity inlets and serve as the transfer point from the network company to the customer's installation. Access is placed outside, so gas supply staff reach the main shut-off device and the meter without arranging a visit with the owner. The configuration is selected from a private house to an industrial site.
- Purpose
- house connection cabinet (gas, water, electricity) — transfer point to the customer's installation; access to the main shut-off device and the meter
- Housing
- fiberglass (polyester resin with glass fiber) per DIN; outer layer without glass fiber
- Properties
- high mechanical strength, low weight, maintenance-free, corrosion-resistant, self-extinguishing; UV resistance per DIN 53 383; frost resistance down to −80 °C
- Design
- double lock; defined breaking point between the plinth and the upper part; door, plinth and front panel removable without tools
Technical specifications
| Purpose | house connection cabinet (gas, water, electricity) — transfer point to the customer's installation; access to the main shut-off device and the meter |
|---|---|
| Housing | fiberglass (polyester resin with glass fiber) per DIN; outer layer without glass fiber |
| Properties | high mechanical strength, low weight, maintenance-free, corrosion-resistant, self-extinguishing; UV resistance per DIN 53 383; frost resistance down to −80 °C |
| Design | double lock; defined breaking point between the plinth and the upper part; door, plinth and front panel removable without tools |
| Configuration | per the customer's inquiry sheet — from a private house to an industrial site |
| Marking | label for gas or flow sensors |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The housing is made to DIN from polyester resin reinforced with glass fiber. The material is strong at low weight, needs no maintenance, does not corrode and is self-extinguishing, and the outer layer without glass fiber does not let fibers out to the surface even after years in the open air. Color resistance to ultraviolet light is confirmed per DIN 53 383, and the surface can be painted if necessary. Frost resistance reaches −80 °C. The standard configuration includes a double lock, a label for gas or flow limiters, and a defined breaking point between the plinth and the upper part, which protects underground utilities in case of a vehicle impact. The door, plinth and front panel are removed without tools. Sizes, pressure and the composition of fittings are not given in the materials, so the valve, regulator and meter are selected per the project.
How to choose
SGR cabinets are made individually, so selection starts with the inquiry sheet. It states which inlets are needed, which gas equipment will stand inside, and whether it is a private house or an industrial site. If a regulator with a medium-pressure inlet is installed in the cabinet, the set is classed as medium-pressure equipment.
Request a price and lead time
SGR — fiberglass house connection cabinets for gas, water and electricity. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What material is the SGR cabinet made of?
Polyester resin reinforced with glass fiber, per DIN. The outer layer is made without glass fiber, so fibers do not come out to the surface.
Down to what temperature is the cabinet frost-resistant?
Down to −80 °C. The self-extinguishing fiberglass does not corrode and needs no maintenance.
Is a separate room for the inlets needed in the building?
No, access to the main shut-off device and the meter is placed in the cabinet, so no room is needed and floor area is saved.
Can the cabinet door be removed without tools?
Yes, the door, plinth and front panel are removed and installed without tools, and the lock is double.
Does the cabinet color fade in the sun?
UV protection has been checked per DIN 53 383, and the color does not change for a long time. The surface can additionally be painted.
Similar products
GBC / GBS / GBS-H / LANCEFIREGBC, GBS, GBS-H, LANCEFIRE gas burners for industrial furnaces, 15–5000 kW
MPA 41xx V2.0MPA 41xx V2.0 and FLW/UV 4x flame sensors, burner control units per EN 298
Selectra M/MRSelectra electronic gas flame modulation systems: M/MR valves (3.4 kPa inlet), amplifiers, sensors, controllers
WGL30/1, WGL40/1WGL30–WGL40 compact dual-fuel gas/oil burners 70–550 kWREQUEST
Need a price, lead time or replacement?