Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

BURNERS AND GAS VALVES

ITG and L9 — actuated gas throttle valves (DN 50–200) and wafer/lug butterfly valves up to 16 bar; VDJ expansion joints

Auxiliary elements of gas trains for flow control and pipe isolation. ITG throttles gas to a modulating burner at 500 mbar, L9 provides a lug butterfly valve up to 16 bar, and VDJ damps vibration at 3 bar.

ITG
motorized throttle valve for modulating and two-stage burners
ITG — media
hot air, natural and town gas, LPG, non-aggressive gases
ITG — Pmax
500 mbar
ITG — regulation
1:10; angle up to 90°; PN 16 flanges DN 50–200, ANSI 150 on request

Technical specifications

ITGmotorized throttle valve for modulating and two-stage burners
ITG — mediahot air, natural and town gas, LPG, non-aggressive gases
ITG — Pmax500 mbar
ITG — regulation1:10; angle up to 90°; PN 16 flanges DN 50–200, ANSI 150 on request
ITG — temperature−40…+70 °C
L9lug-type butterfly valves, Pmax 16 bar between flanges, PN 16 DN 50–200, −10…+80 °C; biogas version
VDJ / VDJFexpansion/anti-vibration joints, 3 bar, thread 1/2″–2″, flanges DN 40–300; gases, biogas, air; −40…+80 °C
ConformityPED 2014/68/EU (L9, VDJ)

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

ITG moves the valve disc with a lever mechanism, and the repositioning time depends on the actuator, which the customer can choose freely or take the recommended one. The valve has low leakage and pressure loss, a regulation range of 1:10, an angle up to 90°, a spherical sector of 30°, ambient temperature from −40 to +70 °C, and works on hot air, natural and town gas, LPG. PN 16 flanges DN 50, 65, 80, 100, 125, 150 and 200 per ISO 7005 and EN 1092-1, ANSI 150 on request. Pressure is up to 500 mbar (50 kPa). L9 is a lug-type disc valve for 16 bar between flanges, PN 16 DN 50–200, from −10 to +80 °C, with a biogas version and ANSI 150, conforming to PED 2014/68/EU. VDJ and VDJF damp vibration and compensate small pipe displacements. The media are gases of three families, biogas and air, pressure up to 3 bar, from −40 to +80 °C. The thread R 1/2–2 inches is male (VDJ) or female (VDJF), with PN 16 flanges DN 40–300 per EN 1092-1. DN 40 and above conform to PED, while small threaded sizes are excluded from CE marking under Art. 4.3 of the directive.

How to choose

If the flow must be regulated smoothly, ITG is taken; to shut off and regulate large gas or air lines, L9 with pressure up to 16 bar. VDJ is installed where burner or pump vibration is transmitted to the pipe. An FM filter is installed at the inlet ahead of them, and for emergency fuel shut-off there is SM/SMO.

Request a price and lead time

ITG and L9 — actuated gas throttle valves (DN 50–200) and wafer/lug butterfly valves up to 16 bar; VDJ expansion joints. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What regulation range does ITG have?

1:10 at an angle up to 90° and pressure up to 500 mbar.

What pressure are the L9 valves rated for?

16 bar between flanges, in sizes PN 16 DN 50–200.

What are VDJ and VDJF for?

They damp vibration and compensate small pipeline displacements, pressure up to 3 bar.

What flanges do the ITG valves have?

PN 16 DN 50–200 per ISO 7005 / EN 1092-1, ANSI 150 on request.

Similar products

Burners and gas valves

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.