Proteus PCS-E — bidirectional energy storage inverter, 1500 V, up to 5.5 MVA
Country: Spain · Model: Proteus PCS-E
The Proteus PCS 4180E, 4360E, 4600E, 4910E and 5150E bidirectional inverters (PCS) convert battery DC to AC during discharge and the other way round during charging. AC power at 40 °C and 1500 V DC is from 4183 to 5153 kVA, up to 5477 kVA at 25 °C, and up to 5535 kVA at 1300 V DC. They are installed in utility-scale battery energy storage systems (BESS).
- Models
- Proteus PCS 4180E / 4360E / 4600E / 4910E / 5150E
- AC power at 40 °C, 1500 V DC
- 4183 / 4365 / 4607 / 4910 / 5153 kVA
- Power at 25 °C
- up to 5477 kVA
- DC voltage
- up to 1500 V (min. 976–1202 V depending on model)
Technical specifications
| Models | Proteus PCS 4180E / 4360E / 4600E / 4910E / 5150E |
|---|---|
| AC power at 40 °C, 1500 V DC | 4183 / 4365 / 4607 / 4910 / 5153 kVA |
| Power at 25 °C | up to 5477 kVA |
| DC voltage | up to 1500 V (min. 976–1202 V depending on model) |
| Max. DC current | 2 × 2227 A |
| DC-side short-circuit withstand | 2 × 250 kA, 3 ms (two DC buses) |
| AC voltage | 690 / 720 / 760 / 810 / 850 V ±15 % |
| Current THD | < 1 % |
| Max. efficiency | 98.57 % |
| Operating temperature | −20…+60 °C |
| Functions | four quadrants, grid forming, synthetic inertia, fast frequency response, black start |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
Rated AC voltage is 690, 720, 760, 810 and 850 V (±15 %), and power is 4183, 4365, 4607, 4910 and 5153 kVA at 40 °C and 1500 V DC, respectively by model. The minimum DC voltage for grid operation is 976–1202 V depending on the model. Maximum efficiency is 98.57 %, standby consumption is below 200 W, and current harmonic distortion is below 1 %. Two independent power modules without galvanic isolation connect two separate batteries, which reduces short-circuit currents on the DC side, and short-circuit withstand is 2 × 250 kA for 3 ms. The design is independent of battery technology; lithium-ion, lead-acid or flow batteries can be used. Operation is four-quadrant, with active and reactive power support, operation in weak grids and microgrids with black start, synthetic inertia and grid forming. Cooling is CoolBrid, operating temperature is −20…+60 °C, and altitude up to 2000 m without derating. 50 MW of PCS-E inverters have been supplied to one customer.
How to choose
Choose the model by power and AC voltage. From the 4180E to the 5150E, power at 40 °C and 1500 V DC rises from 4183 to 5153 kVA, and AC voltage from 690 to 850 V. Two separate batteries on two DC buses reduce short-circuit currents and raise system availability. If you need an inverter for a PV plant without storage, see the Proteus PV 4100–4700 up to 4.7 MVA.
Request a price and lead time
Proteus PCS-E — bidirectional energy storage inverter, 1500 V, up to 5.5 MVA. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
Which models are in the Proteus PCS-E series?
Proteus PCS 4180E, 4360E, 4600E, 4910E and 5150E, with AC power at 40 °C from 4183 to 5153 kVA.
Which battery types does the inverter work with?
The design is independent of technology: lithium-ion, lead-acid, flow and others.
What is the maximum efficiency?
98.57 %, with standby consumption below 200 W.
Does the inverter support grid forming?
Yes: grid forming, synthetic inertia, fast frequency response and black start, in four quadrants.
What is the short-circuit withstand?
On the DC side 2 × 250 kA for 3 ms, because two separate batteries are connected to two buses.
Similar products