SH3–10RL — single-phase hybrid inverter, 3–10 kW, for 48 V batteries

The manufacturer single-phase hybrid inverter rated 3–10 kW for 40–60 V batteries, in other words low-voltage 48 V packs. The battery connects through an isolated converter, and switchover to backup takes ≤ 4 ms. It suits private houses and small commercial sites with a single-phase supply.

Power (SH5RL / SH6RL)
5,000 / 6,000 W, peak 2× for 10 s
Max. PV voltage
500 V, 2 MPPT (40–425 V)
Battery
40–60 V, up to 120–135 A
Backup switchover time
≤ 4 ms

Technical specifications

Power (SH5RL / SH6RL)5,000 / 6,000 W, peak 2× for 10 s
Max. PV voltage500 V, 2 MPPT (40–425 V)
Battery40–60 V, up to 120–135 A
Backup switchover time≤ 4 ms
Max. / European efficiency97.2% / 96.2%
Protection ratingIP65, C5-M
Dimensions / weight532 × 386 × 210 mm, < 19 kg
StandardsIEC 62109-1/-2, EN 50549, VDE-AR-N 4105, CEI 0-21
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408400 (≤7.5 kVA); 8504408800 (>7.5 kVA)
CN code (EU)85044084

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

PV modules connect to 2 MPPTs with a maximum PV voltage of 500 V and an operating range of 40–425 V, so strings are shorter than on three-phase inverters rated 1,000 V. The SH5RL and SH6RL deliver 5,000 and 6,000 W and hold 2× peak power for 10 s, enough to start a pump or an air conditioner. Battery current reaches 120–135 A, maximum efficiency is 97.2% and European efficiency 96.2%. A switchover of ≤ 4 ms puts it on par with a line-interactive UPS, so a boiler or PCs ride through a grid outage. Up to 2 inverters run in parallel, each with up to 4 SBL060 batteries. The inverter works with a diesel generator, microinverters and charging stations. The 532 × 386 × 210 mm unit weighs under 19 kg, is rated IP65 and C5-M, and mounts on a wall indoors or outside. Grid connection follows IEC 62109-1/-2, EN 50549, VDE-AR-N 4105 and CEI 0-21.

How to choose

Start from the battery. The SH3–10RL works only with 40–60 V packs, and for high-voltage 80–460 V batteries on the same single-phase supply take the SH3.0–6.0RS. Size the power to the peak household load, which for 5 and 6 kW means the SH5RL and SH6RL, and a pair of inverters in parallel doubles both power and battery count. With a three-phase supply you need the SH15/20/25T at 15–25 kW with a 100–700 V battery, or the PowerHarbor SH10/12/15TA with its modular battery.

Request a price and lead time

SH3–10RL — single-phase hybrid inverter, 3–10 kW, for 48 V batteries. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What battery voltage does the SH3–10RL need?

40–60 V, meaning low-voltage 48 V batteries such as the SBL060.

How many SH-RL inverters can run in parallel?

Up to 2 inverters, each with up to 4 SBL060 batteries.

How fast does the SH3–10RL switch to backup?

Switchover time is ≤ 4 ms, which most household loads do not notice.

What is the efficiency of the SH5RL and SH6RL?

Maximum efficiency is 97.2% and European efficiency 96.2%.

Can a diesel generator be connected to the SH-RL?

Yes, the inverter works with a diesel generator as well as with microinverters and charging stations.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.