Sunny Central UP — central solar inverter up to 4,600 kVA

The Sunny Central UP central solar inverter delivers up to 4,600 kVA from a DC input of up to 1,500 V. It goes into large ground-mounted PV plants, and up to four units fit into one standard container. The enclosure is rated for outdoor use in all climate zones, so no inverter building is needed.

Output power
up to 4,600 kVA
DC voltage
up to 1,500 V
Cooling
OptiCool
Installation
outdoor, all climate zones

Technical specifications

Output powerup to 4,600 kVA
DC voltageup to 1,500 V
CoolingOptiCool
Installationoutdoor, all climate zones
DC/AC overloadup to 200%
Service lifeover 25 years
More from the manufacturer’s documentation
ModelsSC 4000 UP / SC 4200 UP / SC 4400 UP / SC 4600 UP
AC power at 35 °C / 50 °C4,000 / 3,600 kVA (SC 4000 UP) to 4,600 / 4,140 kVA (SC 4600 UP)
MPP voltage range (25 °C)880–1,325 V (SC 4000 UP) to 1,003–1,325 V (SC 4600 UP)
Max. DC current4,750 A
Max. DC short-circuit current8,400 A
Number of DC inputs24 double-pole or 32 single-pole fused
Nominal AC current (35 °C / 50 °C)3,850 / 3,465 A
Nominal AC voltage600 V (SC 4000 UP), 630 V (SC 4200 UP), 660 V (SC 4400 UP), 690 V (SC 4600 UP)
Grid frequency50 Hz (47–53 Hz) / 60 Hz (57–63 Hz)
Power factor1; adjustable 0.8 overexcited to 0.8 underexcited
Total harmonic distortion< 3% at nominal power
Max. / European efficiency98.8 / 98.6% (SC 4000 UP) to 98.9 / 98.7% (SC 4600 UP)
Degree of protectionIP54 (electronics) / IP34 (air duct, connection area)
Dimensions (W × H × D)2,815 × 2,318 × 1,588 mm
Weight< 3,700 kg
Self-consumption< 8,100 W (max.), < 370 W (standby)
Operating temperature−25 °C to +60 °C (optional from −40 °C)
Storage temperature−40 °C to +70 °C
Relative humidity0–95% non-condensing; 95–100% up to 2 months per year
Installation altitudeup to 1,000 m (optional 2,000 / 3,000 m)
Sound power level93 dB(A); 87 dB(A) with Silencer Kit
Fresh air consumption6,500 m³/h
Auxiliary supplyintegrated 8.4 kVA transformer; 2.5 kVA supply for external loads (optional)
ProtectionDC load-break switch, AC circuit breaker, type I + II surge arresters, lightning protection level III (IEC 62305-1)
InterfacesEthernet, Modbus Client, Modbus Server
Enclosure / roof colorRAL 9016 / RAL 7004
Grid standardsVDE-AR-N 4110/20/30, IEC/EN 62109-1/-2, IEEE 1547, CEI 0-16, EN 50549-2, NTS 2.1, CE
EMC and qualityIEC/EN 55011, IEC 61000-6-2/-4, IEC 62920, FCC Part 15; DIN EN ISO 9001
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408800 (>7.5 kVA)
CN code (EU)85044084

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The range has four models, SC 4000 UP, SC 4200 UP, SC 4400 UP and SC 4600 UP, with nominal AC voltages from 600 to 690 V. The array lands on 24 double-pole or 32 single-pole fused inputs, with a maximum DC current of 4,750 A. A DC/AC ratio of up to 200% lets the array be much larger than the inverter rating. OptiCool moves 6,500 m³/h of air, the electronics are IP54 and the duct and connection area IP34. DC load-break switch, AC breaker and type I + II surge arresters are built in, and an 8.4 kVA transformer feeds the auxiliaries. It ships alone or pre-assembled into a medium-voltage station, with a stated service life of over 25 years.

How to choose

Match the model to the LV winding of the step-up transformer, 600 V for the SC 4000 UP and 690 V for the SC 4600 UP. For a hot site, size by the 50 °C rating, not the 35 °C nameplate. For a BESS beside the plant, the Sunny Central Storage fits the same voltage class, up to 4,600 kVA as UP-XT and 5,000 kVA as UP-S. A field split into scattered blocks suits the Sunny Highpower PEAK3 string inverter, 180 kW at the same 1,500 V DC.

Request a price and lead time

Sunny Central UP — central solar inverter up to 4,600 kVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the maximum output of the Sunny Central UP inverter?

Up to 4,600 kVA for the SC 4600 UP at 35 °C and up to 4,140 kVA at 50 °C. DC input is up to 1,500 V.

How much DC/AC oversizing does the Sunny Central UP accept?

The DC/AC ratio can go up to 200%. Array short-circuit current stays within 8,400 A.

Can the Sunny Central UP be installed outdoors?

Yes, it is rated for outdoor use in all climate zones, from −25 to +60 °C or optionally from −40 °C. The stated service life is over 25 years.

What efficiency does the Sunny Central UP reach?

Peak efficiency is 98.8% for the SC 4000 UP and 98.9% for the SC 4600 UP, with European efficiency of 98.6 and 98.7%.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.