Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

INVERTERS

Solar Ware — central PV plant inverters 1000/1500 V (Samurai, 2220–3360 kW and others)

Solar Ware central inverters for megawatt and gigawatt class PV plants work from 1000 and 1500 V DC fields, with a single unit power from 490 to 3360 kW. More than 29 GW of inverters of this family have been installed worldwide. The ranges are divided by market and standard, from IEC and UL to Japanese JEC.

Samurai 1500 V
2500 kW/kVA, 2700 kW/kVA, 3200 kW/kVA, 3360 kW/kVA
Samurai 1000 V
1833 kW / 2000 kVA; 833 kW / 916 kVA
Solar Ware 3200 (PVH-L3200GR)
1500 V, MPP 875–1300 V, efficiency 98.9 %, NEMA 3R, UL 1741/IEEE 1547
Solar Ware 2700 (PVH-L2700ER/GR)
1500 V, efficiency 98.8 %, IP44/IP54 (IEC) or NEMA 3R (UL)

Technical specifications

Samurai 1500 V2500 kW/kVA, 2700 kW/kVA, 3200 kW/kVA, 3360 kW/kVA
Samurai 1000 V1833 kW / 2000 kVA; 833 kW / 916 kVA
Solar Ware 3200 (PVH-L3200GR)1500 V, MPP 875–1300 V, efficiency 98.9 %, NEMA 3R, UL 1741/IEEE 1547
Solar Ware 2700 (PVH-L2700ER/GR)1500 V, efficiency 98.8 %, IP44/IP54 (IEC) or NEMA 3R (UL)
Solar Ware 2550 / 2220 (PVH-L2550E/L2220E)1500 V, indoor installation, IP21, efficiency 98.8 %, no derating up to 50 °C, IEC 62109
Solar Ware 10001000 V, 1000 kW, efficiency up to 99 %
JEC series (Japan)490–750 kW, 600/1000 V, IP20
Topologythree-level IGBT; hybrid cooling with heat pipes
Grid functionsP/Q and cos φ regulation, FRT/LVRT, night-time VAR mode

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The flagship Samurai series has a new cooling system for extreme temperatures and a multilevel topology that cuts switching losses by 56 %. At 1500 V it covers the 2500, 2700, 3200 and 3360 kW classes, and at 1000 V 1833 kW / 2000 kVA and 833 kW / 916 kVA. The Solar Ware 3200 (PVH-L3200GR) with MPP 875–1300 V and efficiency of 98.9 % is built in a NEMA 3R enclosure to UL 1741 / IEEE 1547, and its hybrid heat pipe cooling needs no fans up to 40 % load. The compact PVH-L2550E and PVH-L2220E for indoor use give 1.4 MVA/m² at IP21 and 98.8 % efficiency, have a built-in DC box, a night-time reactive power mode and IEC 62109-1/-2, IEC 61000-6-2/-4 and CQC certificates. The Solar Ware 1000 delivers 1000 kW with efficiency up to 99 %, and the 490–750 kW models at 600/1000 V with IP20 are built to the Japanese JEC standard. The in-house three-level IGBT topology reduces losses and the size of filter reactors, and a recorder writes fault waveforms to an SD card.

How to choose

First determine the DC field voltage, and the 1500 V option reduces the weight of cables and the number of combiner boxes and inverters per project. A wide MPPT range makes it possible to design a high DC/AC ratio. Then look at the standard and installation place, that is UL and NEMA 3R for an open site or IP21 for an inverter building. For a PV plant with storage there is the PCS at ±2500 kW, and a smaller power step is given by the Solar Ware Ninja at 800–880 kW.

Request a price and lead time

Solar Ware — central PV plant inverters 1000/1500 V (Samurai, 2220–3360 kW and others). We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the highest power of a Solar Ware central inverter?

The largest class of the 1500 V Samurai series has 3360 kW, and the Solar Ware 3200 (PVH-L3200GR) is among the largest central inverters in this voltage class.

What grid functions do Solar Ware inverters support?

Regulation of power factor, active and reactive power, ride-through of voltage and frequency dips and built-in anti-islanding protection. The plant controller manages a fleet of up to 255 inverters.

How do the ER and GR versions of the Solar Ware 2700 differ?

The ER is built to IEC with protection rating IP44 or IP54, the GR to UL in a NEMA 3R enclosure. The efficiency of both versions is 98.8 %.

Do Solar Ware inverters derate in hot weather?

The indoor PVH-L2550E and PVH-L2220E deliver full power without derating up to 50 °C ambient air.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.