SH125CX — commercial hybrid inverter, 125 kW
Country: China · Model: SH125CX
The manufacturer commercial hybrid inverter rated 125 kW / 125 kVA with a DC-coupled 129–880 V battery input at up to 200 A. The PV input takes up to 250 kW at 1,100 V on 10 MPPTs, so the array can be twice the AC rating. It serves factories, warehouses and retail sites where PV runs together with storage.
- Rated AC power
- 125 kW / 125 kVA
- PV input
- up to 250 kW, 1,100 V, 10 MPPT
- Battery voltage
- 129–880 V, current up to 200 A
- Backup switchover
- ≤ 10 ms, 150% overload (10 s)
Technical specifications
| Rated AC power | 125 kW / 125 kVA |
|---|---|
| PV input | up to 250 kW, 1,100 V, 10 MPPT |
| Battery voltage | 129–880 V, current up to 200 A |
| Backup switchover | ≤ 10 ms, 150% overload (10 s) |
| Max. / European efficiency | 98.6% / 98.3% |
| Protection rating | IP66, C5 |
| Dimensions / weight | 1,095 × 795 × 360 mm, ≤ 128 kg |
| Standards | VDE-AR-N 4105/4110, EN 50549, IEC 62109 |
| Customs codes (for reference) | |
| HS code | 8504.40 |
| UKTZED code (Ukraine) | 8504408800 (>7.5 kVA) |
| CN code (EU) | 85044084 |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
PowerKeeper systems are built around this inverter. The battery sits on the DC side, so the array charges it without a double conversion through AC. The inverter handles dynamic tariffs and takes part in virtual power plants (VPP), charging the battery in cheap hours and exporting on the aggregator's command. On grid loss it switches to backup in ≤ 10 ms and carries 150% overload for 10 s, enough to start motors. Maximum efficiency is 98.6% and European 98.3%. The IP66, C5 enclosure measures 1,095 × 795 × 360 mm, weighs up to 128 kg and mounts outdoors. Grid connection complies with VDE-AR-N 4105/4110, EN 50549 and IEC 62109.
How to choose
The deciding parameter is battery voltage. The 129–880 V window fits high-voltage racks of different lengths, and the 200 A limit sets the charging power. Without a battery, the same power class is covered by the grid-tied SG75/110/125CX-P2 with 8 MPPTs on the entry model. Sites at 15–25 kW can use the SH15/20/25T three-phase hybrid with a 100–700 V battery, and a complete kit with storage on the SH125CX is supplied as PowerKeeper.
Request a price and lead time
SH125CX — commercial hybrid inverter, 125 kW. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What battery voltage does the SH125CX support?
129–880 V at up to 200 A.
How much PV can be connected to the SH125CX?
Up to 250 kW on 10 MPPTs at a maximum of 1,100 V.
What overload does the SH125CX carry in backup mode?
150% for 10 s, with backup switchover in ≤ 10 ms.
Can the SH125CX join a virtual power plant?
Yes, it works in VPP schemes and with dynamic tariffs.
What is the efficiency of the SH125CX?
Maximum 98.6%, European 98.3%.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.