Primo GEN24 / Primo GEN24 Plus — single-phase hybrid solar inverter 3–6 kW

The Primo GEN24 single-phase hybrid inverter comes in 3, 3.6, 4, 4.6, 5 and 6 kW ratings for a 230 V grid. It goes into private homes, and the Plus version runs with Reserva, and LG high-voltage batteries and supports full backup.

Grid
1 phase, 230 V
Power
3 / 3.6 / 4 / 4.6 / 5 / 6 kW
MPP trackers
2
DC input voltage
65–600 V

Technical specifications

Grid1 phase, 230 V
Power3 / 3.6 / 4 / 4.6 / 5 / 6 kW
MPP trackers2
DC input voltage65–600 V
Ingress protectionIP66
Dimensions (W×H×D)474×530×165 mm
Backup powerPV Point (up to 3 kW with sunlight, no battery); Full Backup on the Plus version with battery
ProtectionArc Guard (AFCI) in the SC generation, active cooling
More from the manufacturer’s documentation
Battery retrofitUP.storage software upgrade adds battery connection and the Full Backup option to an installed GEN24 (available incl. Ukraine)
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408400 (≤7.5 kVA)
CN code (EU)85044084

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

On the DC side, two MPP trackers accept 65–600 V, so two roof faces with different orientations get separate inputs. Without a battery, the PV Point output still supplies up to 3 kW during an outage while the sun shines, enough for a fridge, a pump or a boiler. Full Backup comes with the Plus version and a battery, with a transfer device added to the panel. On the base version, battery connection is added later with the UP.storage software upgrade, which is also offered in Ukraine. The SC generation carries Arc Guard (AFCI) arc fault protection. Cooling is active, and the IP66 enclosure, 474×530×165 mm (W×H×D), can hang outdoors.

How to choose

Pick the model by array size and by the service entrance. With a single-phase 230 V supply, take the Primo GEN24 rating you need between 3 and 6 kW, and with a three-phase supply the Symo GEN24 at 3–12 kW in the same housing makes more sense. If the battery comes later, install the base version and buy UP.storage when needed. A 15–33.3 kW site with storage calls for the Verto Plus.

Request a price and lead time

Primo GEN24 / Primo GEN24 Plus — single-phase hybrid solar inverter 3–6 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What DC input voltage does Primo GEN24 accept?

65–600 V across 2 MPP trackers.

Does Primo GEN24 work without a battery during a grid outage?

Yes, the PV Point output delivers up to 3 kW while the sun shines. Full Backup requires the Plus version with a battery.

Can a battery be added to the base Primo GEN24?

Yes, on the 3–6 kW inverters battery connection is added with the UP.storage software upgrade.

Can Primo GEN24 be mounted outdoors?

Yes, the enclosure is rated IP66 and actively cooled. It measures 474×530×165 mm and mounts on a wall.

Does Primo GEN24 have arc fault protection?

Yes, SC generation inverters carry Arc Guard (AFCI) protection against arcing in the DC circuits.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.