SUN-SG02HP3 — three-phase hybrid inverters 60–125 kW for business
Country: China · Model: SUN-SG02HP3
A 60–125 kW hybrid inverter for industrial solar plants with storage. From 120 to 250 kW of PV modules and a 160–1000 V high-voltage battery are connected to one unit, and a diesel generator can serve as backup.
- Power
- 60 / 70 / 75 / 80 kW; 100 / 125 kW
- Battery voltage
- 160–1000 V, 2 inputs
- Charge/discharge current
- 80+80 A (60–80 kW), 100+100 A (100–125 kW)
- Connectable PV power
- 120–250 kW
Technical specifications
| Power | 60 / 70 / 75 / 80 kW; 100 / 125 kW |
|---|---|
| Battery voltage | 160–1000 V, 2 inputs |
| Charge/discharge current | 80+80 A (60–80 kW), 100+100 A (100–125 kW) |
| Connectable PV power | 120–250 kW |
| Parallel operation | up to 10 units |
| Customs codes (for reference) | |
| HS code | 8504.40 |
| UKTZED code (Ukraine) | 8504408800 (>7.5 kVA) |
| CN code (EU) | 85044084 |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
The power range of 60, 70, 75 and 80 kW is complemented by the larger 100 and 125 kW models. The battery side has 2 inputs with a 160–1000 V range, so two separate racks can be connected to the inverter. The charge and discharge current is 80+80 A for the 60–80 kW models and 100+100 A for the 100–125 kW models. The permissible PV array power is about twice the inverter rating, and the daytime surplus of generation goes into the battery instead of being cut off by limiting. The inverter works together with a diesel generator, which for enterprises with long outages reduces generator running hours and fuel consumption. Up to 10 inverters are connected in parallel, and with 125 kW models the system goes beyond 1 MW.
How to choose
The model is chosen by the peak load of the enterprise and by the battery voltage, which must fit within 160–1000 V. For a load up to 80 kW the smaller models with 80+80 A current are enough, and for 100–125 kW the current rises to 100+100 A and the battery must withstand it. For houses and small sites the catalog has the lower-power SUN-SG HP3 hybrid series, and a grid-tied solar plant without a battery can do with a string inverter.
Request a price and lead time
SUN-SG02HP3 — three-phase hybrid inverters 60–125 kW for business. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
How many PV modules can be connected to a 125 kW hybrid inverter?
The permissible PV array power in the series is 120–250 kW, that is, about twice the inverter rating.
What battery voltage is needed for the SUN-SG02HP3?
A 160–1000 V range on each of the 2 battery inputs, so two racks can be connected to the inverter separately.
What is the battery charging current in the commercial hybrid inverter?
80+80 A for the 60–80 kW models and 100+100 A for the 100–125 kW models.
Can the hybrid inverter be combined with a diesel generator at an enterprise?
Yes, the series is designed for systems with storage and a diesel generator, which reduces generator running time during outages at sites up to 125 kW.
What power can be reached by connecting inverters in parallel?
Up to 10 inverters work in parallel, and with 125 kW models that is more than 1 MW.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.







