Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

INVERTERS

SUN-G03/G04/G01P3 — three-phase grid-tied inverters 30–136 kW

Commercial-class string inverters rated from 30 to 136 kW for rooftop and ground-mounted solar plants. The maximum efficiency is 98.6–98.8 %, and the number of MPPT trackers is 2–8 depending on the model.

Power
30–36, 40–50, 60–80, 70–110, 120–136 kW
MPPT
2–8
Max. efficiency
98.6–98.8 %
Max. PV voltage
1100 V (G03 — 1000 V)

Technical specifications

Power30–36, 40–50, 60–80, 70–110, 120–136 kW
MPPT2–8
Max. efficiency98.6–98.8 %
Max. PV voltage1100 V (G03 — 1000 V)
Current per MPPT40 A
ProtectionType II SPD DC/AC (60 kW and above)
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408800 (>7.5 kVA)
CN code (EU)85044084

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The range is divided into five bands: 30–36, 40–50, 60–80, 70–110 and 120–136 kW, and this is enough for anything from a warehouse roof to a small ground-mounted plant. The maximum PV array voltage is 1100 V, and 1000 V in the G03 series, which is taken into account when calculating the number of modules in a string. Each tracker accepts current of up to 40 A, so two strings of powerful large-format modules can be connected to one input. Models from 60 kW have built-in type II SPDs on the DC and AC sides, which simplifies the assembly of combiner cabinets. Zero export is needed by businesses that run on their own consumption without selling to the grid, and VSG makes the inverter more stable on weak lines.

How to choose

Inverters are selected so that the array power falls within the range of a series, taking the DC/AC ratio into account, and the number of trackers matches the number of orientations and module types. For sites up to 36 kW the smallest series is enough, and for a large factory roof the 120–136 kW units are taken and several are installed. Small private sites with a single-phase supply are covered by the SUN-G P1 rated 1–10.5 kW with a start-up voltage of 80 V, and if backup from a battery is needed, a hybrid inverter is required.

Request a price and lead time

SUN-G03/G04/G01P3 — three-phase grid-tied inverters 30–136 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the maximum PV voltage of the 30–136 kW commercial inverters?

1100 V for most models and 1000 V for the G03 series, and the string length depends on it.

How many MPPT trackers are there and what is the current per tracker?

Depending on the power 2–8 trackers, each accepting up to 40 A.

Does the commercial inverter have built-in surge protection?

Models from 60 kW have type II SPDs on the DC and AC sides. For the smaller models the need for external SPDs is defined by the design.

What is the efficiency of the SUN-G03/G04/G01P3 three-phase inverters?

The maximum efficiency is 98.6–98.8 % depending on the model.

Can a commercial solar plant work without feeding into the grid?

Yes, zero export mode limits the generation of the 30–136 kW inverters to the level of the enterprise own consumption.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.