Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

INVERTERS

Xtender XTS — compact inverter-charger 0.9–1.4 kVA

The XTS, smallest inverter-charger of the Xtender series, delivers 700–1400 VA for 30 minutes from 12, 24 or 48 V batteries and weighs 8.2 kg. Its IP54 housing suits small off-grid installations in unheated or dusty places.

Models
XTS 900-12, 1200-24, 1400-48
Power (30 min)
700–1400 VA (with ecf 01 fan)
Battery voltage
12 / 24 / 48 V DC
Charge current
up to 35 A

Technical specifications

ModelsXTS 900-12, 1200-24, 1400-48
Power (30 min)700–1400 VA (with ecf 01 fan)
Battery voltage12 / 24 / 48 V DC
Charge currentup to 35 A
Efficiencyup to 93 %
Protection ratingIP54
Dimensions, weight110 × 210 × 310 mm, 8.2 kg
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504408400 (≤7.5 kVA)
CN code (EU)85044087

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The three models, XTS 900-12, 1200-24 and 1400-48, differ in battery voltage, shown after the dash. The upper power figure of 1400 VA applies with the optional ecf 01 fan, and without it there is less thermal headroom. The built-in charger delivers up to 35 A from the grid or a generator on the AC input. Efficiency reaches 93 %. At 110 × 210 × 310 mm the housing fits a telecom cabinet, a van compartment or the utility room of a garden house. IP54 protection removes the need for a separate dry room, and a canopy against direct rain is enough.

How to choose

The model follows from the battery already on site, 12, 24 or 48 V. If peaks exceed 1400 VA, the next step is the Xtender XTM at 1500–4000 VA, though it is IP20 and needs a dry room. When there is no grid or generator and only DC/AC conversion up to 2400 VA is needed, an AJ inverter is the simpler choice.

Request a price and lead time

Xtender XTS — compact inverter-charger 0.9–1.4 kVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Why does the XTS need the ecf 01 fan?

The rated 1400 VA for 30 minutes is given with this fan fitted. Without it the inverter reaches its thermal limit sooner.

Can the Xtender XTS be installed outdoors?

The IP54 housing is protected against dust and splashes, so a sheltered outdoor location is acceptable.

What charge current does the XTS supply?

Up to 35 A from the grid or a generator on the AC input.

How much does the Xtender XTS weigh?

It weighs 8.2 kg at 110 × 210 × 310 mm, so an ordinary wall carries it without a reinforced frame.

Which XTS model fits a 24 V battery?

The XTS 1200-24, built for a 24 V bus. For 12 V there is the XTS 900-12, and for 48 V the XTS 1400-48.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.