CS-IS / CS WAVE MDL — DC/AC inverters 1–24 kVA

The CS-IS inverters of 1000–20000 VA and the modular CS WAVE MDL up to 24 kVA convert the direct current of batteries into alternating current. They power critical AC consumers at power plants, substations and communication facilities.

CS-IS
1000–20000 VA, input 48–220 V DC, THDv < 2 %, Eco mode
CS WAVE MDL
modular 48 V DC → 230 V AC, modules of 1/1.5 kVA, up to 24 kVA, static bypass

Technical specifications

CS-IS1000–20000 VA, input 48–220 V DC, THDv < 2 %, Eco mode
CS WAVE MDLmodular 48 V DC → 230 V AC, modules of 1/1.5 kVA, up to 24 kVA, static bypass

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The CS-IS accepts an input voltage from 48 to 220 V DC, so it is connected to an existing control power battery without an intermediate converter. The distortion factor of the output sine wave THDv is below 2 %, which is enough for computers, control systems and sensitive electronics. Eco mode reduces the inverter own losses during operation. The CS WAVE MDL is built from modules of 1 or 1.5 kVA, which together give up to 24 kVA from a 48 V DC bus with a 230 V AC output. Modules are added in stages as the number of consumers grows. The static bypass transfers the load to the backup mains in case of overload or failure of the inverter part.

How to choose

The first question is the battery voltage. For a 48 V bus both series are suitable, and for 110, 125 or 220 V DC only the CS-IS. If the load will grow or redundancy with modules is needed, choose the CS WAVE MDL. For powers above 24 kVA and bidirectional energy exchange with the grid there is the CS-MV up to 1 MW.

Request a price and lead time

CS-IS / CS WAVE MDL — DC/AC inverters 1–24 kVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What DC input voltage does the CS-IS inverter accept?

From 48 to 220 V direct current, so it connects to most control power batteries.

What is the power of a CS WAVE MDL module?

The modules are 1 or 1.5 kVA, and the system is built up to 24 kVA with a 48 V DC input and a 230 V AC output.

Does the CS WAVE MDL have a static bypass?

Yes, it transfers the load to the backup AC mains in case of a fault or overload of the inverter.

What is the harmonic factor of the CS-IS output voltage?

THDv below 2 %, so the output is suitable for powering electronics and control systems.

Similar products

Inverters

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.